Important telephone numbers

Heating installer

Plumbing system installer

Electrical installer

Fuel supplier

Chimney sweep

To be completed by the heating specialist:

Order No.:

Boiler type:

Neutralisation system:

yes

no

Condensate lifting pump:

yes

no

Set to:
      Natural gas H        Natural gas L

 Liquid gas

Heating pump type:

Heating controller type:

Mixer type:

Separate calorifier type:
Calorifier sensor

Thermostat

Outside temperature sensor
Room temperatur sensor

Combustion air supply

Room

Outside

Heating calculation principles

Lowest outside temperature:

            

°

C

Heat requirement:

  kW

Max. feed temperature:

            

°

C

Operating instructions

UltraGas AM condens (50-350)

4 200 191 / 01

Subject to changes

Hoval LTD

Northgate
Newark
Nottinghamshire NG24 1JN
Phone: 01636 672 711
Fax: 01636 673 532

Summary of Contents for UltraGas AM condens (50-350)

Page 1: ...Liquid gas Heating pump type Heating controller type Mixer type Separate calorifier type Calorifier sensor Thermostat Outside temperature sensor Room temperatur sensor Combustion air supply Room Outs...

Page 2: ...operation of your Hoval UltraGasAMcondens allapplicablelaws regulations and standards must be complied with in particular the regulations of the responsible energy supply authorities In the case of qu...

Page 3: ...eating controller If the boiler is also used for water heating it remains switched on for the whole year Fuel The boiler is only to be operated with the type of gas stated on the rating plate Settings...

Page 4: ...e reset button on the boiler control panel If this is not successful please close the gas cock and call your after sales service or heating installer Absolutely imperative Fault freefunctionisonlyguar...

Page 5: ...ed boiler temperature at the boiler temperature controller Please refer to the section Faults on page 4 if fault lamps light Placing out of operation Place the main SYSTEM switch to 0 Close the gas sh...

Page 6: ...ng nor mal Check 6 3A fuse if all displays remain dark Controls the internal boiler functions Settings and changes are only to be made by the heating specialist The indication flashes if a fault is pr...

Page 7: ...ting Automatic control corresponding to the switching times entered for the 3 nd program longer operating time The room temperature is not reduced in the night Hot water according to clock program 2 S...

Page 8: ...to safely break the connection Note the water quality Drinking water quality the pH value must not exceed 9 5 Fill with water slowly check the water level at the hydrometer or pressure gauge Keep the...

Page 9: ...urn open Is the main switch in the Changeover 6 OFF position Is the clock of the TopTronic Carry out check according to the separate operating correctly set instructions for the heating controller Che...

Page 10: ...oors and windows closed in the winter Close flue flaps when the fire is out Use kitchen and bathroom fans only when steam and odours have to be extracted Ventilate for short periods but frequently Sea...

Page 11: ...d set up for optimal operation Any repairs will be carried out at once with your agreement Amaintenancecontractcarriesawiderange of benefits Your guarantee period is extended when you take out a maint...