4 216 974 / 02
6
Subject to modifications
TECHNICAL INFORMATION, COMPONENTS AND COMMISSIONING
Opening the windows
As a rule, you will not require heating in summer and
thus no heat recovery via your comfort ventilation unit.
HomeVent
®
comfort ventilation unit. You can open doors
and windows as you wish. However, bear in mind that
pollen, insects and dust can enter the house through
open doors and windows.
If you open the windows in winter or during the heating
season, you lose the benefits of your HomeVent
®
comfort ventilation system. Valuable energy escapes
through the windows. The humidity contained in the
outgoing air cannot be recovered, meaning that the
room and becomes drier. Your comfort ventilation
system provides a constant supply of fresh air for your li-
ving area. Your comfort ventilation unit recovers both the
heat and the moisture contained in the air. Your comfort
ventilation system provides a constant supply of fresh air
for your living area. Your comfort ventilation unit reco-
vers both the heat and the moisture contained in the air.
Absence
If you are away for a prolonged period, set your comfort
ventilation to an output of 15% and keep outside doors
and windows closed - in particular in winter so that no
heat is lost. Never switch your comfort ventilation
system off completely in winter.
4.3
Application limits
Application limits for unit setup, weather-protected
(EN 60721-3-3)
3K5 as per EN 50090-2-2
•
Ambient temperature
-16…45 °C
• Ambient humidity
max. 12 g/kg
•
Dew point temp. in installation room
< 15 °C
air conditions
(Moderate outdoor climate EN 60721-2-1)
• Fresh air intake temperature
-20…40 °C
•
Fresh air intake humidity
5…95 % r.F.
•
Extract air temperature
5…35 °C
•
Extract air humidity
5…80 % r.F.
• Extract air humidity
max. 12 g/kg
5 Components
5.1
Ventilation unit
Comfort ventilation unit:
2
3
1
1
Supply air and extract air filter
2
Access panel
3
Prefilter cover
5.2
Appareil de commande
The HomeVent
®
comfort ventilation unit is operated
via an operator terminal. You can choose between two
operator terminals.
4
6
7
or
5
7
6