background image

Other Accessories

Flue gas thermometer

241 237

Suction turbine 

for wall mounting

Centrifugal separator 

set up on boiler 

 

6014 644

Basic kit RAS 41 for BioLyt (50 & 70)

For automatic transfer of pellets from the stor -

age system (store, fabric silo or pellet tank) in to 

the BioLyt pellet storage container. Consisting of 

suction tur bine for wall mounting and centrifugal 

separator mounted on top of the BioLyt boiler.

Filling is time controlled and via a level probe. 

Maximum distance

Output length [m]

maximum possible 

output height [m]

15 to 25

1,8

10 to 15

2,8

  5 to 10

4,5

Sound absorbing hood for suction turbine

for sound reduction

Dimensions:  

H x B x T = 710 x 500 x 354 mm

 

6018 717

Store extract auger complete including 

auger, motor and connectors for vacuum 

pipes. For Hoval BioLyt (50,70).

Consisting of auger, auger channel, auger 

bearing, head piece with drive (geared motor) 

and connectors 

50 mm for vacuum pipes 

with integrated fire protection sleeves.

Type 

Length 

Minimum 

Sections

RAS 

 

room Length

42-1 1300 

1550 

1

42-2  

1800  

2050 

1

42-3  

2300  

2550 

2

42-4  

2600  

2850 

2

42-5  

2800  

3050 

2

42-6  

3100  

3350 

2

42-7  

3600  

3850 

2

42-8  

4600  

4850 

3

42-9  

4900  

5150 

3

42-10  

5400  

5650 

3

6014 645

6014 646

6014 647

6014 648

6014 649

6014 650

6014 651

6014 652

6014 663

6014 664

Fire protection sleeves RAS 29

needed where vacuum air pipes

are passed through walls.

Two sleeves are supplied including fittings.

6014 716

Vacuum pipe RAS 23

earthed, 50mm Dia, 25 m roll.

247 209

Fabric and GRP pellet storage Silos

A range of fabric and GRP pellet storage silos are 

also available, together with an interconnecting 

flexible auger system.

Details available on 

request

12

Hoval BioLyt (50-160)

Summary of Contents for BioLyt 110

Page 1: ...Hoval BioLyt wood pellet boilers Output from 50 to 160 kW Working pressure to 3 bar Technical Data Output range 50 160 kW BioLyt Wood pellet boiler...

Page 2: ...0 3 0 3 0 3 Boiler waterside resistance at 10 K T mbar 25 55 24 39 52 Boiler waterside resistance at 20 K T mbar 7 16 6 10 13 Water flow at 10 K T m h 4 2 6 4 9 1 11 5 13 5 Water flow at 20 K T m h 2...

Page 3: ...m flow connection R 1 2a Boiler return conection R 1 2b System return connection R 1 3a Pellet feed system transfer box RAS 51 3b Optional RAS 41 pellet transportation 50 mm system centrifugal separat...

Page 4: ...ty heat exchanger connections 2 x R 5 Drain R 1 6 Flue gas outlet External 180 mm 7 Induced draught fan 8 Control panel can be fitted right or left side 9 Sight glass 10 Pocket for boiler sensor Rp be...

Page 5: ...000 840 1000 1750 2000 Dimensions BioLyt 50 160 Boiler without casing and insulation all measurements in mm Pallet included for delivery purposes Assembly and delivery The BioLyt boiler is supplied as...

Page 6: ...separate dimensional information on pages 9 10 Use of Buffer Vessel The BioLyt Wood Pellet boiler is designed Engineering to be fully automatic and is supplied with an automatic firing or ignition se...

Page 7: ...1 0 Moisture Content M 10 Size Diameter D Length D 06 Diameter 6mm 20 30mm Sulphur Content S 0 05 Fines 3 15mm into vehicle F 1 0 Bulk Density 650 kg m3 Hoval do not endorse any particular wood pelle...

Page 8: ...store design is adopted it must be such that it Keeps the fuel dry as water ingress will cause the pellets to fall apart and block handling equipment Is located as close as possible to the boiler Has...

Page 9: ...Typical plantroom layouts General arrangement of a BioLyt and fabric silo pellet storage Fabric silo Fabric silo Flexible auger BioLyt wood pellet boiler Maintenance area 9 Hoval BioLyt 50 160...

Page 10: ...ical plantroom layouts General arrangement of a BioLyt and GRP silo pellet storage GRP Silo Flexible auger BioLyt wood pellet boiler Silo fill pipe Silo vent pipe Maintenance area 10 Hoval BioLyt 50 1...

Page 11: ...ow return temperature protection 3 Consists of Biral shunt pump with cable for connection to boiler control panel motorised 3 way valve ball valve on the return ther mometer above the 3 way valve and...

Page 12: ...nd connectors for vacuum pipes For Hoval BioLyt 50 70 Consisting of auger auger channel auger bearing head piece with drive geared motor and connectors 50 mm for vacuum pipes with integrated fire prot...

Page 13: ...ng circuits and solid fuel buffer vessel installation Function key 4 1 flow sensor 3 immersion sensors 6 loose plugs 6012 157 Key Module 5 For 2 mixing circuits and solar plants Function key 5 1 flow...

Page 14: ...TopTronic 2022 995 Immersion sensor KVT 20 5 6S With 5m cable and plug excludes pocket 6012 687 Surface temperature sensor VF204S Usable as flow or return sensor with 4m cable and plug 6012 688 Flow...

Page 15: ...upply DHW Domestic hot water supply ATS Anti thermal siphon dip to prevent gravity circulation SOP Solar circulation pump KSPF Solar tank sensor calorifier buffer KVLF Solar panel flow sensor PT1000 N...

Page 16: ...Sie dieses Shape S i e h a b e n d i e M gl ichkeit ein neues Shape zu n e h m e n hovhovalhovalhov alhovalhovalhoval hovalhovalhovalh ovalhovalhovalho valhovalhovalhova lhovalhovalhovalh ovalhovalhov...

Page 17: ...val equipment contact our service and spares department Responsibilty for energy and environment One stop shopping With us you can easily incorporate gas oil heat pump solar CHP or biomass energy solu...