Cleaning the heating boiler
Cleaning the heating boiler
Daily cleaning
1. Open the combustion chamber door 1 (Figure
7). Remove the fly ash (residues) from the vortex
combustion chamber and from the ash collecting
space below with the wood scraper.
2. Open the lighting door 2 (Figure 7). Clean the grate
and the lateral openings in the loading chamber
lining using the wood scraper (Figure 7a). The ash
layer on the loading chamber floor shall not exceed
2-3 cm in height
3. Use the scraper to level the residues and charcoal
that have entered the vortex combustion chamber
through the grate. They will burn to fly ash in the
next burnout.
Figure 7b
Figure 7a
2
1
4
7
Every 3-4 weeks
(or more often, depending on requirements)
For models
without
heating surface cleaning
1.1 Open cleaning aperture 4 (Figure 7) to the flue gas
collector and clean the thermolytic downstream
heating surface with the cleaning brush. Brush
or vacuum the dust and soot from the flue gas
collector (Figure 7b). For the AgroLyt
®
(20) and
(50) you must first remove the regulator and,
after the cleaning, install it again in the centre.
For models with heating surface cleaning
1.2 The thermolytic downstream heating surface is cleaned
by means of the heating surface cleaning system.
Move the heating surface cleaning lever 5 (Figure
7c) 2-3 times back and forth.
2. Proceed with the steps described in “Daily clean-
ing”.
Figure 7c
5
Loading door
Figure 7