Dear user,thank you for choosing a HOUGHTON caravan air-conditioner. For your ease 

of use and safe maintenance we have included the following symbols in this manual: 

 

 

 

 

 

 

 

 

 

 

 

 

 
 
 
 
 
 

Safety Notices

 

          All  the  contents  with  this 

Warning

  logo  are  about  the  safety  of  the 

product  and  the  user,  the  user  shall  operate  in  strict  compliance  with  the 

instructions. 

 

          All the contents with this 

Prohibition

 logo are about the actions that 

shall  be  prohibited,  or  else  the  machine  may  be  damaged  or  the  user

personal safety may be endangered. 

 

 

Summary of Contents for BELAIRE HB3200

Page 1: ...1 ...

Page 2: ...his manual Safety Notices All the contents with this Warning logo are about the safety of the product and the user the user shall operate in strict compliance with the instructions All the contents with this Prohibition logo are about the actions that shall be prohibited or else the machine may be damaged or the user s personal safety may be endangered ...

Page 3: ...ction 2 Packing List 3 Installation Guidance 4 Instructions for Use 9 Operation Instruction of the Remote Controller 10 Product Maintenance 16 Specification Parameters 17 Exploded Diagram and Parts List 18 Trouble Shooting Guide 20 Circuit Diagram 21 ...

Page 4: ... controller to operate the air conditioner Install the air conditioner in compliance with the instructions of this manual Incorrect installation methods or alteration of the product may cause damage to the product or personal injuries to the user Be careful when installing the unit on the roof of the caravan crawl boards may be required There may be wires between the roof and the ceiling When cutt...

Page 5: ... the remote control to prevent from frequent start or stop of the unit C Condensation For the areas where the air humidity is comparatively low when the warm moist air within the caravan meets with the cold wind from the outlet condensate water may be caused which is also called as sweating In this case make sure the following measures are taken Close all the doors skylights windows and draw the c...

Page 6: ...air inlet duct 1 3 Chassis reinforced support 1 4 Plenum mounting bracket 1 5 Return air filter 1 6 Plenum assembly 1 Accessories fixing devices 7 M8 x 120 mm bolts 4 8 Fixing metal plate 4 9 Large washer 4 10 Plenum screw 4 11 Countersunk head tapping screw 10 2 4 2 5 4 2 6 5 4 2 3 2 8 9 10 7 11 ...

Page 7: ...l be able to support the air conditioner s weight 45kg The opening part of the roof shall be able to support the air conditioner s weight and allow for the corresponding operations Minimum thickness of roof 25mm maximum thickness of roof 85mm If the roof s thickness is beyond the above requirements you can purchase the enhanced length of the inlet air duct and M8 installation bolts from HOUGHTON o...

Page 8: ... that there is sufficient room for the plenum assembly to be installed The installation positions shall be kept away from the skylights heaters or light positions that may affect the air flows 360x 360mm cutting position shall be kept away from connecting position at the roof There shall be a space of 100mm minimum all around the roof top unit to ensure suitable air flow and access for maintenance...

Page 9: ...seal Remove the outdoor unit from the carton and move it to the installation position on the roof Put the outdoor unit over the chassis reinforced support and properly adjust the position to make sure they mate and the four bolt holes on the corners align Installation of chassis reinforced Installation of outdoor unit Note The outdoor unit is about 45Kg lift the outdoor unit at the same time with ...

Page 10: ...ashers and fixing plates to the holes of the 4 corners Start the bolts off using finger effort Ensure all bolts have started correctly for at least 2 or 3 rotations to avoid cross threading Ensure the metal fixing plates align with the corresponding recess in the plenum mounting bracket as the bolts are tightened Evenly tighten up all four bolts Grasp the the air inlet duct loop II of the flexible...

Page 11: ...to as the parts connect together Fix the plenum assembly on the plenum mounting bracket with four ST4 19 pan head screws Remove the screw caps from the plenum Fix the plenum assembly on the plenum mounting bracket with 8 standard equipped countersunk head screws Install return screw caps to the plenum The side of the air filter to highlight the tabs insert slots in the plenum Push the air filter u...

Page 12: ... 2 blades move together Louvers on opposite sides are symmetrical Ajust direction and angle of louver by moving the raised piece in the center of louver Louvers on opposite sides are symmetrical Adjust the louver louver e Louver eeer e er Raised piece Louver close Louver open ...

Page 13: ... the fan FAN Operate in low FAN medium FAN and high FAN in turn to check normal operation To select the COOL mode adjust the set point temperature to three degrees lower than the room temperature the unit will start to blow cold air after the compressor starts To select the HEAT mode adjust the setting temperature as three degrees higher than the room temperature the device will start to blow hot ...

Page 14: ...1 1 Operation Instruction of the Remote Controller Remote controller Plenum display Touch screen key Temperature display Mode display ...

Page 15: ...ess the MODE key select the mode Press the FAN key Select Low Medium High FAN circularly and the plenum will display and the indoor environment temperature Low Medium High COOL mode Press the MODE key select the mode Press the down key to set the temperature lower than the room temperature Press the FAN key to select different speed and the plenum will display and the setting temperature FAN FAN ...

Page 16: ...select the mode Press the up key to set the temperature higher than the room temperature Press the FAN key to select different speed and the plenum will display and the setting temperature AUTO mode Press the MODE key select the mode Press the up or down key to set different temperature Press the FAN key to select different fan speed and the plenum will display and or and and the setting temperatu...

Page 17: ... and Fahrenheit Turn off Press the on off key again unit turns off and the plenum will display nothing Note When in the AUTO mode according to the difference between the setting temperature and the environmental temperature the plenum will display and automatic heating or and automatic cooling in the same time ...

Page 18: ... back functions Low temperature heating will cause frosting during when it is normal to show DF on the plenum When the environmental temperature is lower than 0 the heating effect is reduced suggest adopting other ways for heating in the same time If the device is left unused for long time please remove the batteries from the remote controller 2 Plenum operation Note In case the plenum touch scree...

Page 19: ...recommended that the air conditioner is operated regularly to ensure good performance In the case of a caravan that will not be used regularly then the unit should be operated for 20 30 minutes every 6 Months In case the caravan is parked outdoors for long time suggest using protective jacket to protect the outdoor unit of the air conditioner from wind and sun Screw check It is recommended that th...

Page 20: ...ed current for heating A 5 2 5 4 Maximum input power W 1650 1700 Maximum current A 7 2 7 4 Maximum design pressure kPa 2900 2900 Minimum design pressure kPa 1840 1840 Maximum air flow l s 150 150 Installed weight kg 45 3 45 3 Outdoor unit dimension Height 223mm Width 850mm Length 1122mm Plenum unit dimension Height 49mm Width 515mm Length 575mm Notes 1 All parameters listed are subject to change w...

Page 21: ...1 8 Exploded Diagram and Parts List ...

Page 22: ...pe fixed plate 2 19 4708 1701 05 Electrical box 1 1 20 4708 1701 06 Electrical box lid 1 21 4708 1701 07 Electrical box 2 1 22 4708 1701 06 Electrical box lid with same 20 1 23 4708 1240 00 Electronic control components 1 24 TDQ 04204 Compressor run capacitor 1 25 4678 1701 02 Compressor start capacitor 1 26 4678 1701 03 PTC 1 27 4709 0000 02 Air duct brace 1 28 4679 0000 04 Air duct 1 29 30 4709 ...

Page 23: ... compressor has a delay start for three minutes More time would be needed for starting heating under extremely cold condition To make sure the filter is clean Turn on the fan to high FAN to obtain the maximum capacity To make sure all the doors and windows as well as the sunroof are closed Curtains and awnings can be used to decrease the heating load In case there is 0 or any messy code when the g...

Page 24: ...21 Circuit Diagram ...

Page 25: ...22 ...