6
OPERATION OF CONTROLS
BEFORE INSTALLING HOUGEN CUTTER
IMPORTANT: Before turning on the machine, it is important that the operator understands the interrelated
functions of the SAFETY SWITCH, MAGNET SWITCH, AND MOTOR SWITCHES.
READ SAFETY SWITCH INDICATOR LIGHT INSTRUCTIONS PREVIOUS PAGE.
SAFETY SWITCH
— Located in base of drill. Enables motor operation only when magnet is
properly seated on a clean and fl at work surface. Turns motor off if switch
detects lift of unit.
MAGNET ON/OFF SWITCH
— Energizes and De-Energizes the magnetic base and activates the
safety switch. Motor can now be started by pushing the motor START switch.
MOTOR START/STOP SWITCHES
— Starts and Stops the motor (See instructions previous page).
POWER/MANUAL FEED SWITCH
— Enables or disables Power Feed Mode.
1. Place Magnetic Drill on clean, fl at steel plate that is at least 3/8” thick.
2. Plug unit into proper AC power source.
DO NOT use with DC Power.
3. Locate the Magnet
ON
and
OFF switches
and the motor
STOP
and
START
switches.
4.
NOTE: A loss of power will de-energize the magnetic base and deactivate the motor.
When power is restored, the magnet will reenergize, however, the motor START switch
must be depressed before the motor will start.
������
�����
�������������������������