Collet
Collet Retainer
Tap
Jaws
8
9
Select the correct size Collet
for the Tap that will be used
and install it into the bottom
of the Tap-Matic.
Collet 10807 - Taps #10 thru 1/2”
Collet 10808 - Taps 1/2” thru 3/4”
Thread the Collet Retainer
onto the Tap-Matic holding the
Collet in place. Do not tighten
the Collet Retainer until the
next step.
Install the appropriate Tap
up thru the Collet Retainer
until the flat sides of the
Tap are in the Jaws of the
Tap-Matic. Tighten the
Jaws so the Tap is held.
Then tighten the Collet
Retainer with the supplied
wrenches.
Adjust the long Stop Screw
to the appropriate depth and
lock in place with the lock
nut.
CAUTION
When the Tap is working down into the material the
Stop Arm will rotate and make contact with the Drill
Housing on the opposite side that is shown. When the
Tap direction changes and the Tap is working out of the
material it will rotate again to the opposite side. Keeps
hands clear of the Stop Arm while operating.
Stop Arm
Stop Screw
NOTE:
Installation of the Tapping Attachment is the same on either system covered by the first page.
4
Install the Stop Arm to the Tap-Matic Assembly
with the 3 Button Head Screws supplied with the
Tap-Matic. Thread the Adapter (40226) into the top of
the Tap-Matic Assembly and install the 5/16-18 X 3/8
Set Screw (40256) into the side of the Adapter.
Install the 1/4-20 X 2-1/2 Set Screw (02432) and
1/4-20 Lock Nut (10859) into the Stop Block as shown.
Mount the Stop Block Assembly to the Magnet with
the supplied 3/8-24 Hex Bolts and tighten with a 9/16
Wrench.
Slide the Adapter and
Tap-Matic Assembly up onto
the Motor Spindle at the base
of the Motor making sure the
Spindle sits down in the notch
of the Adapter. While holding
the Assembly up, tighten the
5/16-18 X 3/8 Set Screw at
the top of the Adapter.
5
6
7
Continued on next page