9
1
2
3
4
5 6
7a
7b
7c
08446
Pressurized Coolant Assembly
Item
Part #
Description
Qty
1
08557
Pressurized Coolant Block
1
2
05646
Fitting-Qk Connect Male
1
3
04807
O-Ring
1
4
05630
Coolant Bottle Assembly
1
Eng
lish
OPTIONAL PRESSURIZED COOLANT BOTTLE
MAINTENANCE
In order to minimize wear on moving parts and to insure smoother operation and longer life for your magnetic drill, the following
maintenance should be done periodically, based on use.
1. Regularly tighten all fasteners and replace all worn parts.
2. Check motor brushes and replace if worn.
3. Check power cord and cord from panel to motor and, if cracked or frayed, return to an authorized repair center for replacement.
4. Apply grease to the slide rods, brass gibs, and the feed gear. For best results use Shell Cyprina-RA or equivalent.
5. The safety switch plunger should be clean and lubricated with penetrating oil periodically. As necessary remove the magnet
from drill and remove safety switch assembly from magnet. Push the plunger out of magnet. Clean out any debris from inside an
around plunger hole in magnet. Coat the plunger with anti-seize. Replace plunger and safety switch assembly and tighten down
screws. Replace magnet into drill housing.
When everything is ready to go (Magnet ON and Impactors seated), open the Adjustment Needle to provide a generous
flow of cutting fluid until a puddle approximately the diameter of the cutter being used is developed on the workpiece.
Once this initial supply of cutting fluid is established on the workpiece, adjust the flow to a steady drip.
OPERATION OF CUTTING FLUID RESERVOIR
1
2
3
4
4
Reference Only
#40062 Tie Bar
located on the
machine
Reference Only
Existing Screws
#40108