HotWire HWGL1 Instructions Download Page 4

Hotwire

 

Thermostat

Technical Information

To enter into the setting menu please follow the steps below:

Step 1. Turn the thermostat off by pressing 

POWER

 

Step 2.  Press 

MENU

 you will then see menu 01.

Step 3. Use the up and down arrows to adjust the sensor selection which is Menu 01(Air sensing;Air and Floor, or Floor only)

Step 4. Press 

NEXT 

 to move to the next Menu and once you have all the menu options set,

Setp 5. Press 

DONE

 to accept and store.

Configuration Menu

Menu #

Feature

Explanation

Adjustment

(Press up & down buttons to adjust)

01

Mode/Sensor Selection

This thermostat is a combination model which allows you

to choose 3 different modes.

A mode = Air Sensing Only(Has built in sensor)

AF mode = Air & Floor sensing (Floor probe must be installed)

F mode = Floor Sensing(Floor probe must be installed)

A / AF / F

02

Switching differential

The number of degrees difference before switching.

The default is 1°C which means the thermostat will switch

the heating on 0.5°C below the set temperature and will turn

it off 0.5°C above the set temperature.With a 2°C differential

the heating will switch on 1°C below the set temperature

and will switch off 1°C above the set temperature.

1 Deg C, 2 Deg C....10 Deg C ( 1 Deg C by default)

03

Air Temp Calibration

This is to recalibrate the air temp if required

-1 Deg C = decrease 1 °C , 1 Deg C = increase 1 

Deg C 

04

Floor Temp Calibration

This is to recalibrate the floor temperature if required

-1 Deg C = decrease 1 °C , 1 Deg C = increase 1 

Deg C 

05

Temperature Readout 

(AF mode only)

This gives you the option to show the Air Temp,

Floor Temp or to show both Air & Floor at intervals

A = Show Air Temperature

F = Show Floor Temperature

A-F = Show Floor and Air Temperature in 5 sec 

intervals

06

Maximum Floor Temp

( AF Mode only)

This is to protect the floor surface

20 Deg C - 40 Deg C (40 Deg C by default)

07

Temperature Format

This allows the temperature to be set to show 

Deg Celsius or Deg Fahrenheit

Deg C / Deg F

08

Clock Format

You can select the clock to show in either 12 

or 24 hour time

24 (default), 12- hour or 24-hour clock format

09

Frost Protection

This is to avoid your room temp going below 5 DegC

On = activated, Off = deactivated

10

5+2 / 7 Day mode

 

This allows you to programme either 5 days at once, 

then the 2 days of the weekend separately, 

or a full 7 days at the same time or 7 days separately.

01 = 5 + 2 Day Programming

02 = 7 Day Programming

11

Auto/Manual mode 

selection

This allows you to choose Auto / Manual mode

00 = Auto mode

01 = Manual mode

12

Software version

This is for review only

V1.0

13

Minimum temperature 

limit

This gives you the option to change the minimum set 

temperature

5 °C~ 20 °C (5 °C by default)

14

Maximum temperature 

limit

This gives you the option to change the maximum set 

temperature

This gives you the option to change the maximum set 

temperature

15

Sensor type selection

This allows you to match your thermostat to different sensor

10 = NTC10K(by default), 100= NTC100K, 

3=NTC3K

16

Not at use

Reserved for future use

17

Reset

This allows you to reset your thermostat to factory default

Press and hold down button until you see RES on 

screen