BXA • 8.917-989.0 • Rev. 12/13
9
PRESSURE
W
ASHER
OPERA
T
OR’S MANU
AL
OPERATING INSTRUCTIONS
STEP 1:
Check engine oil level. Oil level should be level with the bottom
of the oil fi ller neck. Be sure the machine is level when checking the oil
level. (Refer to the engine's operating manual included with machine.)
We recommend that the oil be changed after the fi rst 5 hours of use, then
once every 50 hours.
Note:
Improper oil levels will cause low oil sensor
to shut off engine.
IMPORTANT! Do not run engine with high or low
oil levels as this will cause engine damage.
STEP 2:
Remove shipping cap
and install oil dipstick. Check
pump oil level by using dipstick
or observe oil level in oil window
(if equipped).
Use 40 wt. non
detergent oil.
STEP 4:
Connect garden hose
to the cold water source and turn
water on completely. Never use
hot water.
STEP 6:
Slide the fuel valve lever to the "ON" position.
When the engine is not in use, leave the fuel valve in
the "OFF" position.
STEP 5:
Trigger the spray gun to
eliminate trapped air then wait for
a steady fl ow of water to emerge
from the spray nozzle.
STEP 3:
Fill gas tank with unleaded
gasoline. Do not use leaded gaso-
line.
STEP 7:
Move the choke lever to the "Choke" posi-
tion (on a warm engine, leave the choke lever in the
run position).
Oil Dipstick
Dipstick
Oil Window
Gas
Tank
Cold
Water
Source
Garden
Hose
Choke
Lever
Fuel
Valve
Choke
Off
On
Choke
Run
Fuel
Valve