8.914-000.0, 8.917-410.0, 9.800-340.0 • Rev. 09/10
5
PRESSURE W
ASHER
OPERA
T
OR’S MANU
AL
ASSEMBLY INSTRUCTIONS
STEP 2:
Before installing nozzle,
turn on water supply and run
machine allowing water to flush
through the system until clear.
STEP 5:
Connect garden hose to
the cold water source.
Cold
Water
Source
Garden
Hose
STEP 6:
Pull the spring-loaded
collar of the wand coupler back
to insert your choice of pressure
nozzle. Release the coupler collar
and push the nozzle until the collar
clicks. Pull the nozzle to make sure
it is seated properly.
Pressure
Nozzle
Wand
Coupler
Wand
Collar
STEP 1:
Attach the high pressure
hose to the spray gun using tefl on
tape on hose threads.
Safety
Latch
Spray
Gun
High Pressure
Hose
DipStick
STEP 7:
Remove shipping cap and
install oil dipstick. Check pump oil
level by using dipstick or observe
oil level in oil window (if equipped).
Use 40 wt. (non detergent) oil.
STEP 4:
Connect the garden hose
to pump water inlet. Inspect inlets.
CAUTION: Do not run the pump
without water or pump damage
will result.
Pump
Water Inlet
Garden
Hose
STEP 3:
Connect the high pressure
hose to the high pressure outlet.
Push coupler collar forward until
secure.
High
Pressure
Outlet
High Pressure Hose
Coupler
Collar