3. Press the
MODE
▲
button to reach EXIT+. Press
ON
▲
to return to the main
menu.
30 Day Reminder:
You must check your spa water at least once every 30 days. To remind you, the ACE
water care icon and OUT menu will flash.
1. Test and balance spa water
using a 5-way test strip. Measure chlorine, pH,
Total Alkalinity, and Hardness levels, to determine if your water is in the “OK”
ranges specified for the ACE system. Adjust as needed. Reduce Hardness to 50
ppm using the Vanishing Act calcium remover if needed.
2. Confirm output setting.
Press the
MODE ▲
button several times from the
home screen to reach the ACE menu. Press the
ON ▲
button to enter the ACE
system menu.To clear the 30 day reminder, press the
MODE ▲
button until
OUTS appears. Press the
ON ▲
button to change the output value. Press the
OFF
▼
button twice to set and confirm new output value. Reset your Output
setting as needed to maintain a 1-5 ppm chlorine residual.
3. Superchlorinate/Shock spa water.
Add granular sodium dichlor as directed on
the bottle to bring the spa water to 5ppm. Allow jets to run for 5 minutes per jet
system, rotating any diverter valves.
The 30-day timer resets any time the output setting is adjusted. If the output setting
is not confirmed at the 30 day reminder, the ACE system will automatically lower the
output setting.
Day 30: Maintenance reminder, reconfirm output level
Day 33: Output setting automatically lowered to 2
Day 40: Output setting automatically lowered to 1 (Vacation/Low Output Mode).
Status Test:
The status test measures how optimal the ACE system is performing. To ensure
optimal performance, keep the salt level in the OK range (use salt test strips to verify)
and clean the ACE cell a minimum of every three months.
A Status test can indicate when the cell needs to be clean, or if there is too much or
too little salt in the water. The Status reading updates every 6 hours, and prior to a
Boost. To refresh the Status, press the
MODE ▲
button several times from the home
screen to reach the ACE menu. Press the
ON ▲
button to enter the ACE system
menu, press the
MODE ▲
button until STAT appears. Press the
OFF
▼
button twice
to set and confirm the Status test. STAT will flash while testing.
When the test is complete the menu will display one of the following:
OK RANGE: STAT 3-6
Your cell and water are working together to clean the water. Regularly check the cell
for calcium scale and test the salt level in the water.
ACE Salt Water Sanitizing System