Adjust the detection area according to the following diagrams.

1. Detection Area Pattern

<Side View>

Area Adjusting Screw

Scale Marks inside

10 for both sides
(RIGHT / LEFT)

10

5

5

10

Door Side

Door Side

-5-

Lens Box (Upper Hatch) for adjusting
Detection Area. (RIGHT / LEFT)

-4-

6. Adjusting the detection area

CAUTION

The illustrated detection areas represent the actual position of the infrared beams. The actual detection area observed will vary depending
on the sensor installation environment, objects been detected and sensor settings. Please confirm the detection area and sensitivity after
installation without fail.

CAUTION

Do not touch the surface of the lens while adjusting. If the lens becomes dirty, wipe the lens clean by using neutral detergent.

(Unit : m)

4.0

0.5

1.0

1.5

2.0

0.5

1.0

Door Center

0.3

0.5

2.0

3.0

2.5

2.5

3.5

10

10

Side View

<Front View> Without Prism

<Front View> With Prism

Door Side

Attach the prisms covering the lenses.

10

1.0

2.8

2.0

1.5

0.5

2.0

2.5

0.5

1.0

1.5

2.0

2.5

2.5

(Unit : m)

Front View

With Prism

10

Adjust the 2

nd

 Row when Doorway detection function is ON.

When using prisms :

Without Prism

W1

2200
2500
2800

2560

3270

2920

H

More than 2800

Prism does not work

Depth “D“ is unchanged
Mounting height is MAX 2.8m
Detection by Area Mask is prohibited

Area Adjusting Screw

Towards Outside

Towards Door Side

A 360  roll of the Screw adjusts Depth Angle 3 .

Mounting Height

300mm

2000mm

Area Adjusting Estimation List

Distance between Door

Center and Sensor

400mm

500mm

3000mm
4000mm

6
3
2

9
5
3

10

7
5

Mounting height

Moving distance on the floor

2000mm

150mm

100mm

200mm

3000mm

4000mm

Moving distance by 360  roll of the Screw

H

W1

W2

2200
2500
3000
4000

2100

1550

3800

2850

2400

1750
2100
2800

W3

1000
1100
1300
1730

D

1100
1250
1500
2000

<Top View>

With Prism

(Unit : mm)

(Unit : mm)

2. Adjusting Detection Area

 Set Dip Switch     5  to <Doorway>

 Set Dip Switch

3   4   5 to <Adjustment>

3 4

5

Adjustment

In this setting, only 2

nd

 Row is valid.

Initialization indicating LED blinks.

 Referring to the Area Adjusting Estimation List below, fix the approximate

     angle by Area Adjusting Screw.

 Adjust 2

nd

 Row not to overlap with the Doorway with the door opened.

     (See the figure on the right)
     Detection Area should be adjusted looking at Indicator LED by using
     a beam finder or reflection sheet.

 Turn Area Adjusting Screw as below.

3

 After finishing setting of 2

nd

 Row, adjust Dip Switch

3   4   5 as necessary. Re-set Power-ON after confirming no one is in the detection area.

When Open/Close the door, if hunting occurs or caution Indicator LED regarding the 2

nd

 Row overlapping with the door blink (Both Power

     Indicating LED and Operation Indicating LED blink at the same time), adjust the detection area away from the door by Area Adjusting Screw.

CAUTION

After adjusting Detection Area, be sure to Re-set Power-ON, and carry out Initializing and Automatic Sensitivity Adjustment again.

CAUTION

When selection <Normal> of 1

st

 Row Setting, the 1

st

 Row detects in an usual activation mode.

Please adjust the 1

st

 Row not to detect the Door.

How to attach prisms (as an option)

Both sides of the prism lens are
set into the lens box.

If the prisms become dirty, wipe them clean by
using neutral detergent.
Do not use thinner or alcohol.

Check whether the prisms are set firmly after
fixing them.

Mounting height is less than 2.8m in case of using
prisms.

Each of the
2 prisms are
attached.

Setting Area Mask <Wide> in case of using
prisms.

CAUTION

CAUTION

CAUTION

CAUTION

CAUTION

X

X

1.0

4.0

3.0

2.0

1.5

0.5

2.0

2.5

0.5

1.0

1.5

2.0

10

10

2.5

2.5

3.5

Front View

(Unit : m)

W3

W2

W1

Door Side

Door Side

W1

Y

2

nd

 Row

2

nd

 Row should be not to detect Door.

Just under the sensor