Drilling may cause electric shock. Be careful of hidden wires inside the ceiling.

Gray codes used for Power, yellow codes used for
Output. Both do not have polarity of electrode.

Connector of the Unit

Output

Yellow

5. Dip Switch Settings

If  there  is  the  wiring  inside  the
ceiling,  install  the  body  more
than 1m away the wiring.

Please read followings and understand the functions well to do the proper settings.

 8    Self-Monitoring (Dip Switch     6)

 Self diagnostic function can be selected.

2s

Presence Timer

Dip Switch

-2-

-7-

6R 

 2R

4. Mounting & Wiring Information

WARNING

1. Cut out the Mounting Template provided into
    the appropriate size for the sensor.

126

130 mm

300 

 500 mm

2. Connect wires

Wiring Cable

Yellow

Power

Gray
Gray

3. Mount the body into the ceiling by Fixing
    Screw.

Turn clockwise

Door

4. Dip Switch Settings and adjustments.

7. Sensitivity Settings (Pre-caution on Power-ON)

6. Adjusting the detection area

5. Please see                                               to confirm
    operations.

8. Verification of Operation

CAUTION

6. Attach the Front Panel to the body.

Turn clockwise

5. Dip Switch Settings

10s

60s

1

2

6R

Quantity of

    Detection Rows

5R

4R

3

4

5

3R

2R

Frequency

A

B

C

6

7

8

D

E

F

Dip Switch

H

Sensitivity

M

L

1

2

Snow

 3m

Mounting Height

3

2.5 

 4m

ON

4

OFF

Doorway

5

Normal

OFF

Self-Monitoring

6

ON

6

R

Door

Side

5

R

4
R

3
R

2
R

1
R

Adjustment

1

st

 Row Setting - Doorway

Door

Side

2
R

1

st

 Row Setting - Normal

Door

Side

1
R

CAUTION

In case that you carry out settings not in
a way mentioned here, mal-function
will be occurred.

Operation

Indicator

Power

Indicator

Power ON

ON

OFF

Detecting

ON

ON

2nd Row Overlapped

Both Blink

Alternate Blink

Self-Monitoring

Operation Indicator / Power Indicator LED

Initialization Indicator

During

ON

After

OFF

Pre-Power ON

OFF

OFF

Adjusting Mode

Blink

After rechecking, there is still a problem, please contact us or your dealer.

Problem

Cause

Solution

Door does not
operate.

Door operates
intermittently.

Door operates when
no-one is present.

Sensor Connector.

Tighten connector or reconnect.

Power Supply Voltage.

Apply proper voltage to the sensor.

Sensor is very dusty or covered with raindrops etc.

Clean the sensor. (Do not use thinner or alcohol to clean sensor.)

Sensitivity is too low.

Detection area incorrect.

Increase sensitivity by adjusting <Dip Switch   1 2>.

Adjust Dip Switch and Area Mask.

Moving objects in the detection area.

Detection area too far from the Door, detecting
people passing by.

Another sensor is installed near by.

Ensure different frequency setting for each other.

The condition of Detection Area is varying.
  *Dust / Dirty
  *Spread out / Remove a mat
  *Snow (footprints)

Detection State may continue during the time setting for presence
detection (the Door remains open) and becomes normal afterward.
Set the presence detection time shorter, re-set the power supply.

10. Indicator Function

Initialization Indicator LED

11. Trouble Shooting

Adjust detection area or move away the moving object.

Adjust Dip Switch and Area Mask.

Sensitivity is too high.

Decrease sensitivity by adjusting <Dip Switch   1 2>.

Default Setting

Default Setting

X

Y

Y

Initialization Indicator LED (Red)

Power Indicator LED (Red)

Operation Indicator LED (Red)

Y

Y

Y

 1    Presence Timer (Dip Switch

1 2)

The sensor will detect a stationary object only for the time set by the Presence Timer. (2s, 10s, 60 seconds,

)

If set to 

, the period is infinity in case of the 1

st

, 2

nd

, 3

rd

 Row, 2 seconds in case of the 4

th

, 5

th

, 6

th

 Row.

X

 2    Quantity of Detection Rows (Dip Switch

3 4 5)

 Pattern Depth is adjustable by selecting 2R / 3R / 4R / 5R / 6R (all rows).

If set to <adjustment>, mode is special for adjusting and the inner row only is valid. (please see 6.2)

X

 3    Frequency (Dip Switch

6 7 8)

When more than two sensors are installed in close proximity to each other, select different frequencies for each sensor from A to F to prevent
interference.
If you used our H/MH/ML/L 4 frequency changed model, please be noted H coincides with A and MH with B and ML with C and L with D.

X

4    Sensitivity (Dip Switch

1 2)

Normal position is <M>. If the Door operates even though no person is in the detection area, please set to <L> (Sensitivity will be lower).
When there is an influence by snow or insects, set to <Snow>.

Y

5    Mounting Height (Dip Switch

 3)

Adjust the mounting height 2 

 3 m or 2.5 

 4 m.

Y

 6    Doorway Detection when closed (Dip Switch     4)
        Doorway Detecting mode when 1

st

 Row Setting (Dip Switch     5) is set to <Doorway>.

        ON : Detects Doorway when the Door is closed. Normal position is <ON>
        OFF : Not detect Doorway when the door is closed. Combined with other security systems, <OFF> is useful.

Y

 7    1

st

 Row Setting (Dip Switch     5)

Doorway : Detects Doorway realizing the Door movement. Normal position is <Doorway>.
Normal : Detects as an usual Activation Row. In this case, adjust the detection area of the 1

st

 Row away from the door.

Y

ON

1

2

3

4

5

6

7

8

ON

1

2

3

4

5

6

Y