EN16005
Note
EN16005
8
OFF
CAUTION
CAUTION
WARNING
CAUTION
■
Other symbols to be aware of.
Disregarding this symbol may result in injury
or damage to equipment.
Disregarding this symbol may result in
serious injury or death.
This symbol shows
a situation
which should be avoided
.
This symbol shows an instruction which
must be followed.
This symbol shows a situation which
you should be aware of.
WARNING
CAUTION
■
The symbols below indicate dangers.
2. Remove the
Cover.
User Manual
3H-IR14C
Motion and Presence Sensor
Before using this sensor, read this user manual in detail.
During the lifetime of the product, keep the manual and refer it when needed.
3. MOUNTING PRECAUTIONS
To prevent malfunction mount as indicated.
1. Mount lower than 3m
5. Install in
vibration free
environment
4. Mount where rain or
snow will not fall directly
on unit.
1. Accumulation of snow or
water on the floor.
3. Mount where no direct
and reflected sunlight
shine onto the sensor
2. Environment is humid or
steamy.
Cover
1. DESCRIPTION
User Manual
Accessories
Mounting Template
Cable
Body
Base
3.0m
9. Place the Cover on sensor and
wipe the
sensor clean
.
Be careful not to move the sensor
Body when attaching the Cover.
8. House the Connector
in the space provided.
1. Determine the
mounting position
of the device and
attach the Mounting
Template. Drill the
mounting and wiring
holes.
5. MOUNTING & WIRING INFORMATION
Drilling may cause electric shock.
Be careful of hidden wires inside the door engine cover.
7. Set the following parameters
6-1. Wiring to a door controller that can test the sensor.
4. Install the Base with
the Mounting Screws.
5. Attach the Body to the
Base.
3. Remove the Mounting
Screws and the Body from the
Base .
6. DIP SWITCH SETTINGS
7. APPLYING POWER
If the sensor is exposed to excessive rain or snow,
protect it with a Hotron weather cover.
In the following cases, the sensor may
detect without the presence of a person
3. Objects placed in the
detection area.
4. Pets / Animals enter the
detection area.
③
Safety Output
Refer to
section 11. TIMING CHART OF EVENTS
for full details on Safety Output.
⑤
Monitor Mode
Set to
“
Snow
”
in instances where false door activations can result from blowing snow,
leaves or rubbish in the detection zone. It should be noted that sensitivity to detecting
pedestrians may also be reduced.
①
Quantity of Detection Rows
The number of rows of detection can be set to 4, 3, 2 or 1 depending on detection area
required.
②
Frequency
When more than two sensors are installed in close proximity to each other, select
different frequency setting for each sensors to prevent cross interference.
It will take approximately 6s for dip
switch setting changes to take effect.
If you carry out the following when the power is turned on, the sensor will detect for 30s.
Before turning on the power, wire the door controller to the sensor.
No moving object
Power-
on/Reset
Presence detection
If there is a moving object in detection area after Power-on / reset, the sensor will be in motion detection mode.
If there is no moving object in detection area after Power-on / reset, the sensor will be in presence detection mode.
Moving object
Motion detection
5 s
No moving object
5 s
Remove
moving
object
Presence detection
Motion
Detection
2 s
⑥
TEST Input
When connected to a door controller without a TEST
Input, set to
“
OFF
”
. When connected to a door
controller with the TEST Input, set to
“
ON
”
Refer to
section 11. TIMING CHART OF EVENTS
.
Place or remove a
mat in the detection
area.
Adjust the angle of Body.
Adjust the width of the detection area.
Adjust the sensitivity.
Default Setting
:
☆
☆
①
Quantity of
Detection Rows
R4
R3
R2
R1
1 2
☆
⑤
Monitor
Mode
Normal
7
1
2
3
4
5
6
7
8
Snow
COMPLIED STANDARDS
DIN18650-1:2010
EN 12978:2003 +A1:2009
EN 16005:2012
EC type examination No. **** ********
☆
②
Frequency
A
B
C
D
3 4
Setting required to conform with EN16005.
Special attention is required when this symbol is
shown.
2. Ensure no moving
objects are in the detection
area
6-2. Wiring to a door controller that cannot test the sensor.
Set
“
TEST Input
”
dip switch setting 8 to “ON”
Ref
section 6. DIP SWITCH SETTINGS
.
Set
“
TEST Input
”
dip switch setting 8 to
“
OFF
”
Ref
section 6. DIP SWITCH SETTINGS
.
Mounting Screws
(2 pcs.)
Potentiometer
(Sensitivity Volume)
Connector
LED
Indicator
Area
Mask
Detection
Window
Dip
Switch
4. TECHNICAL SPECIFICATIONS
Specification may change without prior notice.
0 to 5[degrees]
R4~R1
Normal / Snow
4 Frequencies
2 [s]
Wide / Narrow
Installation Height
Sensitivity adjustment
3.0 [m]
Available
Presence Timer
Depth adjustment
Angle
Row
Width adjustment
Monitor mode
Frequency
Model Name
3H-IR14C
AC12V : 1.1[VA]Max AC24V : 1.3[VA]Max
DC12V : 70 [mA]Max DC24V : 40 [mA]Max
Standby
(Green)
R3,R4 Detecting
(Blue)
R1,R2 Detecting
(Red)
Door movement is detected
(Orange)
Indicates a change of dip switch settings
(Fast flashing Orange )
Internal Sensor Error
(Fast flashing Green/Red )
Reflected infrared signal from the floor is very low
(Flashing Green/Red )
Supply Voltage
Power Consumption
Output
AC/DC 12~24 [V]±10% 50/60 [Hz]
S : Silver , BL : Black
Output Holding Time
LED Indicator
Operating Temperature
Weight
Color
Approx 180 [g]
-20 ~ +60 [
℃
]
Approx 0.5 [s]
2. EXTERNAL DIMENSIONS
Active Infrared Reflection
Detection Method
[mm]
Form A Relay Contact
DC50[V] 0.1[A] (Resistance load)
Form A Relay Contact
DC50[V] 0.1[A] (Resistance load)
Safety
(R1,R2)
Activation
(R2,R3,R4)
Below 80 [%]
DC24V
:
6 [mA] Max
TEST Input
Operating humidity
Category
2 , performance level D according to EN
ISO 13849-1:2008
IP Rate
IP54 (With Base)
0.1 ~ 0.2 [s]
Response Time
30 [s]
R1,R2
R3,R4
210
15
75(Standard Mounting Pitch)
35
10
28.5
5
9
section 6. DIP SWITCH SETTINGS
section 8. ADJUSTING DETECTION PATTERN
section 9. ADJUSTING SENSITIVITY
section 10. VERIFICATION OF OPERATION
section 11. TIMING CHART OF EVENTS
☆
⑥
TEST Input
OFF
8
ON
③
Safety
Output
④
Activation
Output
☆
N.O.
5
N.C.
☆
N.O.
6
N.C.
④
Activation Output
Refer to
section 11. TIMING CHART OF EVENTS
for full details on Activation
Output.
To comply with EN16005 set to “ON”.
8
ON
ON
Without
TEST
With
TEST
0v
OFF
Without
TEST
0v
Note
EN16005
Note
Sensor
’
s
Cable
Cable
Red
Black
White
Green
Yellow
Gray(+)
Activation
Output
AC/DC
12~24V ±10%
Safety
Output
N.O./N.C.
Power
(
Non Pole
)
TEST Input
TEST Input (+)
TEST Input (-)
Blue
Brown(-)
N.O./N.C.
Sensor
’
s
Cable
Cable
Red
Black
White
Green
Yellow
Gray(+)
Activation
Output
AC/DC
12~24V ±10%
Safety
Output
Power
(
Non Pole
)
Blue
Brown(-)
Do not connect
Do not connect
N.O./N.C.
N.O./N.C.
Set in a manner suitable for operation.