FAULT
SUBCODE
DESCRIPTION
CHECKS
F24
71h
Tangential fan in diode mode.
1
Check that the tangential fan is working properly.
2
Check that the motor fan is working properly.
3
Check connectors on component and main PCB
sides.
4
Check the state of cables on both fans.
5
Replace the Main PCB.
72h
Tangential fan short circuited or
disconnected.
73h
Tangential fan circuit open.
74h
Tangential fan FB failure.
75h
Tangential fan general failure.
76h
Tangential fan in diode mode +
master relay jammed.
81h
Circular fan in diode mode.
82h
Circular fan short circuited or dis-
connected.
83h
Circular fan circuit open.
84h
Circular fan FB failure.
85h
Circular fan general failure.
86h
Circular fan in diode mode + master
relay jammed.
F27
01
Function selector short circuited.
1
Check connectors on component and board
sides.
2
Check the state of cables.
3
Replace function selector.
4
Replace the Main PCB.
02
Function selector circuit open.