Dryer exhausting information
For complete information see installation instructions packed with dryer.
Important note:
5.8 cu. ft., 6.0 cu. ft. and 7.0 cu. ft. dryers do not require additional parts to convert to bottom
or side venting. Unitized models do not require a kit for side venting.
Ducting materials
For best performance, this dryer should be vented with 4" diameter all rigid metal exhaust duct. If “all rigid
metal” duct cannot be used, then “flexible all metal” venting can be used, but it will reduce the maximum
recommended duct length. The following kit or parts are available from your local service organization.
Kit WX8X75 – 7' aluminum duct and 4' hood, short tail.
(OR individual parts):
WX8X65 7' aluminum flex duct only
WX8X58 4' clamps (2)
WX8X67 4' exhaust hood
See installation instructions for complete information.
Exhaust length calculation:
1. Determine the number of 90° turns needed for your installation. If you exhaust to the side or bottom of
dryer, add one turn.
2. The maximum length of 4' rigid (aluminum or galvanized) duct which can be tolerated is shown in the
table. The maximum lengths for flexible ducts are less than for rigid duct.
See table in installation instructions. A turn of 45° or less may be ignored. Two 45° turns within the duct
length should be treated as a 90° elbow. A turn over 45° should be treated as a 90° elbow.
Exhausting the dryer to the outside is strongly recommended
to prevent large amounts of moisture
and lint from being blown into the room. Gas dryers or any dryer located in a closet must be exhausted to
the outside.
Caution:
For personal safety do not terminate exhaust into a chimney, under any enclosed house floor
(crawl space), or into an attic, since the accumulated lint could create a fire hazard or moisture could cause
damage. Never terminate the exhaust into a common duct or plenum with a kitchen exhaust, since the
combination of lint and grease could create a fire hazard.
Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird nesting, etc. The
wall cap must also be located at least 12" above the ground or any other obstruction with the opening pointed
down. Other terminations, such as louvered wall boxes, are acceptable provided they are equivalent to a
4" opening dampered wall cap.
NVLR223EG – Hotpoint 5.8 Cu. Ft. Extra-Large Capacity Electric Dryer
Dryer Exhausting Information – Use Metal Duct Only
Vertical and Horizontal Ducting
Specification Revised 12/06
470150
Listed by
Underwriters
Laboratories
A
A
B
2-1/2
4
GE Dryer Vent
A
B
2-1/2
4
GE Dryer Vent
Best Performance
Maximum Length of 4" Dia.
Rigid Metal
Duct
Maximum Length of 4" Dia.
Flexible Metal
Duct
Exhaust Hood Type
Exhaust Hood Type
Domestic
Dryer Models
Number
of
90°
Turns
A
4" Opening
B
2-1/2"
Opening
A
4" Opening
B
2-1/2"
Opening
7.0, 6.0 and 5.8
Capacity Models
all Electric Dryers
0
1
2
3
4
90 ft.
60 ft.
45 ft.
35 ft.
25 ft.
65 ft.
45 ft.
35 ft.
25 ft.
15 ft.
55 ft.
40 ft.
30 ft.
20 ft.
15 ft.
45 ft.
30 ft.
20 ft.
15 ft.
10 ft.
7.0, 6.0 and 5.8
Capacity Models
all Gas Dryers
0
1
2
3
90 ft.
60 ft.
45 ft.
35 ft.
60 ft.
45 ft.
35 ft.
25 ft.
55 ft.
40 ft.
30 ft.
20 ft.
45 ft.
30 ft.
20 ft.
15 ft.
Spacemaker
®
Models
DSKS433EB
DSKS333EC
DSKP333EC
WSM2780H
0
1
2
3
46 ft.
38 ft.
31 ft.
24 ft.
37 ft.
30 ft.
22 ft.
15 ft.
30 ft.
25 ft.
20 ft.
16 ft.
24 ft.
20 ft.
14 ft.
10 ft.
Spacemaker Model
WSM2700H
0
1
2
3
56 ft.
46 ft.
34 ft.
32 ft.
42 ft.
36 ft.
28 ft.
18 ft.
30 ft.
22 ft.
16 ft.
10 ft.
22 ft.
14 ft.
10 ft.
5 ft.
Spacemaker Models
WSM2420D
WSM2480D
0
1
2
43 ft.
33 ft.
23 ft.
36 ft.
26 ft.
16 ft.
30 ft.
24 ft.
16 ft.
24 ft.
18 ft.
10 ft.