Dryer exhausting information

For complete information see installation instructions packed with dryer.

Important note: 

 

5.8 cu. ft., 6.0 cu. ft. and 7.0 cu. ft. dryers do not require additional parts to convert to bottom  

or side venting. Unitized models do not require a kit for side venting.

Ducting materials

 

For best performance, this dryer should be vented with 4" diameter all rigid metal exhaust duct. If “all rigid 

metal” duct cannot be used, then “flexible all metal” venting can be used, but it will reduce the maximum 

 recommended duct length. The following kit or parts are available from your local service organization. 

Kit WX8X75 –  7' aluminum duct and 4' hood, short tail.  

(OR individual parts):
WX8X65 7' aluminum flex duct only

WX8X58 4' clamps (2) 

WX8X67 4' exhaust hood

See installation instructions for complete information.

Exhaust length calculation:

 

1.  Determine the number of 90° turns needed for your installation. If you exhaust to the side or bottom of 

dryer, add one turn.

2.  The maximum length of 4' rigid (aluminum or galvanized) duct which can be tolerated is shown in the 

table. The maximum lengths for flexible ducts are less than for rigid duct.  

See table in installation instructions. A turn of 45° or less may be ignored. Two 45° turns within the duct 

length should be treated as a 90° elbow. A turn over 45° should be treated as a 90° elbow.

Exhausting the dryer to the outside is strongly recommended

 to prevent large amounts of moisture 

and lint from being blown into the room. Gas dryers or any dryer located in a closet must be exhausted to  

the outside.

Caution:

 For personal safety do not terminate exhaust into a chimney, under any enclosed house floor 

(crawl space), or into an attic, since the accumulated lint could create a fire hazard or moisture could cause 

damage. Never terminate the exhaust into a common duct or plenum with a kitchen exhaust, since the 

 combination of lint and grease could create a fire hazard.
Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird nesting, etc. The 

wall cap must also be located at least 12" above the ground or any other obstruction with the opening pointed 

down. Other terminations, such as louvered wall boxes, are acceptable provided they are equivalent to a  

4" opening dampered wall cap. 

NVLR223EG – Hotpoint 5.8 Cu. Ft. Extra-Large Capacity Electric Dryer

Dryer Exhausting Information – Use Metal Duct Only 

Vertical and Horizontal Ducting

Specification Revised 12/06

470150

Listed by 

Underwriters 

Laboratories

A

A

B

2-1/2

4

GE Dryer Vent

A

B

2-1/2

4

GE Dryer Vent

Best Performance

Maximum Length of 4" Dia. 

Rigid Metal

 Duct

Maximum Length of 4" Dia. 

Flexible Metal

 Duct

Exhaust Hood Type

Exhaust Hood Type

Domestic

Dryer Models

Number

of

90°

Turns

A

4" Opening

B

2-1/2"

Opening

A

4" Opening

B

2-1/2"

Opening

7.0, 6.0 and 5.8 

Capacity Models 

all Electric Dryers

0

1

2

3

4

90 ft.

60 ft.

45 ft.

35 ft.

25 ft.

65 ft.

45 ft.

35 ft.

25 ft.

15 ft.

55 ft.

40 ft.

30 ft.

20 ft.

15 ft.

45 ft.

30 ft.

20 ft.

15 ft.

10 ft.

7.0, 6.0 and 5.8

Capacity Models 

all Gas Dryers

0

1

2

3

90 ft.

60 ft.

45 ft.

35 ft.

60 ft.

45 ft.

35 ft.

25 ft.

55 ft.

40 ft.

30 ft.

20 ft.

45 ft.

30 ft.

20 ft.

15 ft.

Spacemaker

®

 Models

    DSKS433EB

    DSKS333EC

    DSKP333EC

    WSM2780H

0

1

2

3

46 ft.

38 ft.

31 ft.

24 ft.

37 ft.

30 ft.

22 ft.

15 ft.

30 ft.

25 ft.

20 ft.

16 ft.

24 ft.

20 ft.

14 ft.

10 ft.

Spacemaker Model

    

    

    

    WSM2700H

0

1

2

3

56 ft.

46 ft.

34 ft.

32 ft.

42 ft.

36 ft.

28 ft.

18 ft.

30 ft.

22 ft.

16 ft.

10 ft.

22 ft.

14 ft.

10 ft.

5 ft.

Spacemaker Models

    WSM2420D

    WSM2480D

0

1

2

43 ft.

33 ft.

23 ft.

36 ft.

26 ft.

16 ft.

30 ft.

24 ft.

16 ft.

24 ft.

18 ft.

10 ft.

Reviews: