Installation Instructions

1  PREPARING FOR INSTALLATION
    OF NEW DRYER

Minimum Clearance Other Than Alcove or Closet Installation

Minimum clearance to combustible surfaces and for air opening are: 0 in. clearance both sides and 1 in. rear. Consideration 

must

 be given to provide adequate clearance for proper operation and service.

2  GAS REQUIREMENTS

EXTERNAL
DUCT
OPENING

GAS
INLET
PIPE

CSA (AGA) APPROVED
NEW FLEXIBLE GAS
LINE CONNECTOR

DUCT
TAPE

DUCT
TAPE

4" METAL DUCT

TIP: Install your dryer before installing your washer.
This will allow better access when installing dryer exhaust.

DISCONNECTING GAS

TURN GAS
SHUT-OFF
VALVE TO THE
OFF POSITION. 

DISCONNECT AND DISCARD OLD
FLEXIBLE GAS CONNECTOR
AND OLD DUCTING MATERIAL.

The use of old flexible connectors can cause leaks and 
personal injury. Always use new flexible connectors when 
installing gas appliances.

WARNING 

INTERNAL DUCT
OPENING

       WARNING - NEVER REUSE OLD

FLEXIBLE CONNECTORS.

REMOVING LINT FROM  WALL
EXHAUST OPENING 

CHECK THAT EXHAUST
HOOD DAMPER OPENS
AND CLOSES FREELY.

WALL

2

TILT THE DRYER SIDEWAYS
AND REMOVE  THE FOAM
SHIPPING PADS BY
PULLING AT THE SIDES 
AND BREAKING THEM
AWAY FROM THE DRYER
LEGS. BE SURE TO
REMOVE ALL OF THE
FOAM PIECES AROUND
THE LEGS.

• Installation must conform to local codes and ordinances, 

or in their absence, the NATIONAL FUEL GAS CODE, 
ANSI Z223.

• This gas dryer is equipped with a Valve & Burner Assem-

bly for use only with natural gas. Using conversion kit 
WE25X0217, your local service organization can convert 
this dryer for use with propane (LP) gas. ALL CONVER-
SIONS MUST BE MADE BY PROPERLY TRAINED 
AND QUALIFIED PERSONNEL AND IN AC-
CORDANCE WITH LOCAL CODES AND ORDI-
NANCE REQUIREMENTS.

• The dryer must be disconnected from the gas supply

piping system during any pressure testing of that system 
at a test pressure in excess of 0.5 PSI (3.4 KPa).

• The dryer must be isolated from the gas supply piping 

system by closing the equipment shut-off valve during 
any pressure testing of the gas supply piping of test
pressure equal to or less than 0.5 PSI (3.4KPa).

WARNING 

DRYER GAS SUPPLY CONNECTION

2"

2-5/8"

3/8" NPT MALE THREAD GAS SUPPLY

NOTE: Add to vertical dimension
the distance between cabinet
bottom to floor.

GAS SUPPLY

• A 1/8-in. National Pipe Taper thread plugged tapping, ac-

cessible for test gauge connection, must be installed imme-
diately upstream of the gas supply connection to the dryer. 
Contact your local gas utility should you have questions on 
the installation of the plugged tapping.

• Supply line is to be 1

• You must use with this dryer a flexible metal connector listed

/2-in. rigid pipe and equipped with an 

  accessible shut-off within 6 ft. of, and in the same room 

with, the dryer. 

• Use pipe thread sealer compound or Teflon tape 

appropriate for natural or LP gas.

connector ANSI Z21.24 / CSA 6.10. The length of the
connect shall not exceed 3 ft. 

• Connect flexible metal connector to dryer and gas supply.

• Open shut-off valve.

 

Summary of Contents for NBXR333GGWW - 6.0 cu. Ft. Gas Dryer

Page 1: ...t be performed by a qualified installer service agency or the gas supplier o not allow children on or in the appliance Close supervision of children is necessary when the appliance is used near childr...

Page 2: ...ed with a Valve Burner Assem bly for use only with natural gas Using conversion kit WE25X0217 your local service organization can convert this dryer for use with propane LP gas ALL CONVER SIONS MUST B...

Page 3: ...nd fittings are designed for use only on the original installation and are not to be reused for another appliance or at another location Keep flare end of adaptor free of grease oil and thread sealant...

Page 4: ...gid Metal Rigid Metal 90 Feet 60 Feet 45 Feet 35 Feet 0 1 2 3 55 Feet 40 Feet 30 Feet 60 Feet 45 Feet 35 Feet 20 Feet 25 Feet 45 Feet 30 Feet 20 Feet 15 Feet Flexible Metal Use only for short run inst...

Page 5: ...EXHAUSTING IF SPACE IS LIMITED USE THE INSTRUCTIONS IN SECTION 12 TO EXHAUST DIRECTLY FROM THE LEFT SIDE OR BOTTOM OF THE CABINET WE RECOMMEND THAT YOU INSTALL YOUR DRYER BEFORE YOUR WASHER THIS WILL...

Page 6: ...3 in front and rear Minimum vertical space from floor to overhead cabinets ceiling etc is 52 in Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq in of open are...

Page 7: ......

Page 8: ...PENING 14 SERVICING REMOVE 4 HINGE SCREWS ROTATE DOOR 180 AND REINSTALL REMOVE 4 HOLE PLUGS AND PLACE THEM IN THE HOLES ON THE OPPOSITE SIDE WARNING LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICI...

Reviews: