background image

Listed by 

Underwriters 

Laboratories

Dryer Exhausting Information   – Use Metal Duct Only 

Vertical and Horizontal Ducting

  

90 ft. 

60 ft.

  

60 ft. 

45 ft.

6.8 and 5.8 cu. ft.  

45 ft. 

35 ft.

Capacity Models 

35 ft. 

25 ft.

all Electric Dryers 

25 ft. 

15 ft.

  

90 ft. 

60 ft.

6.8 and 5.8 cu. ft. 

60 ft. 

45 ft.

Capacity Models 

45 ft. 

35 ft. 

all Gas Dryers  

30 ft. 

25 ft.

Portable/Stationary Models 
     DSKS433EB 

46 ft. 

37 ft.

     DSKS333EC 

38 ft. 

30 ft. 

     DSKP333EC 

31 ft. 

22 ft. 

     WSM2780H 

24 ft. 

15 ft.

  

56 ft. 

42 ft.

  

46 ft. 

36 ft.

Unitized Model 

34 ft. 

28 ft.

     WSM2700H 

32 ft. 

18 ft.

Unitized Models 

43 ft. 

36 ft.

     WSM2420D 

33 ft. 

26 ft.

     WSM2480D 

23 ft. 

16 ft.

Number

of

90°

Turns

Maximum Length of  

4"-Dia.

 Rigid Metal

 Duct 

Exhaust Hood Type

Domestic  

Dryer Models

A

4" Opening

B

2-1/2" 

Opening

Best Performance

B

2-1/2

4

A

A

For complete information, see installation instructions packed with your dryer.

Ducting Materials: 

For best performance, this dryer should be vented with 4" diameter all rigid metal exhaust duct. 

If rigid metal duct cannot be used, then UL-listed flexible metal (semi-rigid) ducting can be used 

(Kit WX08X10077). In special installations, it may be necessary to connect the dryer to the 

house vent using a flexible metal (foil-type) duct. A UL-listed flexible metal (foil-type) duct may 

be used ONLY in installations where rigid metal or flexible metal (semi-rigid) ducting cannot be 

used AND where a 4” diameter can be maintained throughout the entire length of the transition 

duct. Please see installation instruction packed with your dryer for complete instructions when 

using flexible metal (foil type) ducting. 

Exhaust Length Calculation: 

1.  Determine the number of 90° turns needed for your installation. If you exhaust to the side or 

bottom of dryer, add one turn.

2.  The maximum length of 4' rigid (aluminum or galvanized) duct which can be tolerated is 

shown in the table.

   A turn of 45° or less may be ignored. Two 45° turns within the duct length should be treated 

as a 90° elbow. A turn over 45° should be treated as a 90° elbow.

Dryers 

must

 be exhausted to the outside.

Caution:

 For personal safety do not terminate exhaust into a chimney, under any enclosed 

house floor (crawl space), or into an attic, since the accumulated lint could create a fire hazard or 

moisture could cause damage. Never terminate the exhaust into a common duct or plenum with 

a kitchen exhaust, since the combination of lint and grease could create a fire hazard.
Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird nesting, 

etc. The wall cap must also be located at least 12" above the ground or any other obstruction 

with the opening pointed down.

HTDP120ED – Hotpoint

®

 6.8 cu. ft. capacity DuraDrum

 electric dryer

Specification Created 1/12

470164

Reviews: