*with dry gas 15°C 1013 mbar
** Propane P.C.S=50,37 MJ/Kg
*** Butane P.C.S=49,47MJ/kg
Natural G20 P.C.S=37,78Mj/m³
Table of burner and nozzle specifications
3. Remove the knob.
4. Tighten or loosen the adjustment screws on the
outside of the thermostat pin (
see figure) until the
flame is small but steady.
!
If the appliance is connected to liquid gas, the
bypass screw must be adjusted to minimum.
5. Turn the knob from the MAX position to the MIN
position quickly or open and shut the oven door,
making sure that the burner is not extinguished.
Adjusting the gas oven burner’s minimum setting:
1. Light the burner (
see Start-up and Use).
2. Turn the knob to the minimum position (MIN) after
it has been in the maximum position (MAX) for
approximately 10 minutes.
Adapting the oven
Replacing the oven burner nozzle:
1. Remove the oven compartment.
2. Slide out the protection
panel A
(
see diagram).
3. Remove the oven burner
after unscrewing the screws V
(
see figure).
The whole operation will be
made easier if the oven door
is removed.
4. Unscrew the nozzle using a
special nozzle socket spanner
(
see figure) or with a 7 mm
socket spanner, and replace it
with a new nozzle that is
suited to the new type of gas
(
see Burner and nozzle
specifications table).
A
V
Replacing the Triple ring burner nozzles
1. Remove the pan supports and lift the burners out of
their housing. The burner consists of two separate
parts (see pictures).
2. Unscrew the nozzles using a 7 mm socket spanner.
Replace the nozzles with models that are configured
for use with the new type of gas (see Table 1). The
two nozzles have the same hole diameter.
3. Replace all the components by completing the
above operations in reverse order.
• Adjusting the burners’ primary air :
Does not require adjusting.
• Setting the burners to minimum:
1. Turn the tap to the low flame position.
2. Remove the knob and adjust the adjustment screw,
which is positioned in or next to the tap pin, until the
flame is small but steady.
3. Having adjusted the flame to the required low
setting, while the burner is alight, quickly change the
position of the knob from minimum to maximum and
vice versa several times, checking that the flame
does not go out.
Liquid Gas
Natural Gas
Thermal Power
kW (p.c.s*)
By-Pass
1/100
(mm)
Nozzle
1/100
(mm)
Flow
g/h
Thermal Power
kW (p.c.s*)
By-Pass
1/100
(mm)
Flow
g/h
Burner
Diameter (mm)
Nominal
Reduced
***
**
Nominal
Reduced
Oven
-
2.60
1.00
50
79T2A
189
186
2.60
0.70
112 T2
248
TC
130
3.30
1.50
61
2x65
240
236
3.30
1.50
2x99
314
Semi Rapid
(Medium) (S)
75
2.00
0.40
30
69
145
143
2.00
0.40
104
190
Auxiliary
(Small) (A)
55
1.00
0.40
30
50
73
71
1.00
0.40
78
95
Suppy
Pressures
Nominal (mbar)
Minimum (mbar)
Maximum
28-30
20
35
37
25
45
20
17
25
methane nozzles are available on request but not as an accessory