25 of 29
Indesit
Company
Service Manual UK
English
CONNECTINNG LOW END ADAPTOR - 2007 Version with the updated double cable
You can now programme the CL2005 ES Power Module via the serial port at the rear of the appliance
Photo 5. This eliminates the necessity to disassemble the control panel. This harness leads directly to
J013 on the ES Power Module behind the control panel, refer to page 38 and 39 for the ES wiring
diagram.
BEFORE PROCEEDING
UNPLUG
THE APPLIANCE FROM THE ELECTRICITY SUPPLY
Step 1
- Insulate the
unused cable
Photo 4
Step 2
- Connect the cable to the serial port
IMPORTANT:
INSULATE
THIS UNUSED CABLE
BEFORE APPLYING
POWER TO THE
APPLIANCE
UPGRADED
DOUBLE CABLE
LOW END
ADAPTER
HARDWARE Key
Black Serial type shown
Photo 5
NOTE: -
Ensure the serial port cover is refitted after programming.