22 of 29
Service Manual UK
Indesit
Company
English
MAIN BOARD PROGRAMMING - For Modules with fixed EEProm
PROGRAMMING (Using Smartcard Reader / Card)
If the Main Module has been replaced during a repair the board will require programming using the fol-
lowing method.
1.
Do NOT connect the machine to electrical supply.
2.
Insert the pre-programmed card into the Card reader. Care must be taken at this point to ensure the
card is inserted correctly with the Chip on the card facing the PCB of the Reader.
3.
Insert the Reader and Card into module connection port.
4.
Connect the machine to the Electrical supply
, the LEDs on the Smart Card Reader will light in this
sequence:
a)
Red ON: Good Communication between Smart Card Reader and Card.
b)
Red OFF; Green Blinking: Download taking place.
c)
At end, Green ON ---> Download OK.
d)
At end, Red ON or RED Flashing ---> Download NOT OK.
5.
Programming Complete, disconnect the machine from Electrical supply.
6.
Remove the Smart Card Reader.
NOTE:
The main module does not have
a physically replaceable EEProm.
Programming a Main Board
There are a number of ways the board
can be programmed - some of which are
not applicable to certain markets.
Types of programming:
1.
Handheld Terminal (Not UK)
2.
Emit / Memwriter (UK Indesit Service
Engineers)
3.
Smart Reader and Smart Card
(certain areas of UK market) see
photo.
Smart Card
Smart Card
this card holds the
program file and can
only be used ONCE.
Reader