Installation Instructions for your built-in Hob

The following instructions are intended for the installer so that
the installation and maintenance procedures may be followed
in the most professional and expert manner possible.
Important: Disconnect the appliance from the electrical
supply before performing any maintenance or regulation
upkeep work.

Positioning for gas hob
Important:
 this unit may be installed and used only in
permanently ventilated rooms according to the British
Stancards Codes Of Practice: B.S. 6172 / B.S. 5440, Par.
2 and B.S. 6891 Current Editions. The following
requirements must be observed:
a) The hob must not be installed in a bed sitting room with

a volume of less than 20m

3

. If it is installed in a room of

volume less than 5m

3

 an air vent of effective area of

110cm

2

 is required, if it is installed in a room of volume

between 5m

and 10m

3

 an air vent of effective airvent of

50cm

2

 is required, while if the volume exceeds 11m

3

 no

airvent is required. However, if the room has a door or a
window which opens directly to the outside no air vent is
required even with the volume is between 5m

3

 and 11m

3

.

b) Intensive or prolonged use of the appliance could mean

that extra ventilation is needed, such as the opening of
a window or a more powerful fan.

c) If there are other fuel burning appliances in the same

room, B.S. 5440 Part 2 Current Edition, should be
consulted to deter mine the requisite air vent
requirements.

Installation of built-in gas hobs
The gas hobs are prepared with protection degree against
excessive heating of type X, the appliance can therefore
be installed next to cabinets, provided the height does not
exceed that of the hob. For a correct installation of the
cooking hob the following precautions must be followed:
a) The hob may be located in a kitchen, a kitchen/diner or

bed sitting room, but not in a bathroom or shower room.

b) The furniture standing next to the unit, that is higher than

the worktops, must be placed at least 110mm from the
edge of the board.

c) The minimum distance combustible material can be

fitted above the hob in line with the edges of the hob is
420mm. If is fitted below 420mm a space of 50mm
must be allowed from the edges of the hob. The
minimum distance combustible material kitchen units
can be fitted directly above the hob is 700mm.

Min. 600 

mm.

HOOD

min. 650 mm. with hood

min. 700 mm. without hood

Min. 420 

mm.

Min. 420 

mm.

HOOD

min. 650 with hood

min. 700 without hood

LESS THAN 420

LESS THAN 420

min. 50

min. 50

d) The dimensions of the room for the furniture must be

those indicated in the figures. Fixing hooks are provided
which allow to place the hob plate on work tops that
measure from 20 to 40 mm in thickness. To obtain a

good fixing of the hob plate it is advisable to use all the
hooks supplied.

555 mm

55 mm

475 mm

Fastening Clamps - Assembly Diagram

20

30

Clamp Position for

Clamp Position for

H=20mm top

H=30mm top

Front

40

Clamp Position for
H=40mm top

Back

N.B: Use the clamps contained in the "accessory kit."
e) In the event the hob is not installed above a built-in oven,

a wood panel must be inserted as insulation. This panel
must be placed at least 20 mm from the bottom of the
hob itself.

Important: When installing the hob above a built-in oven,
the oven should be placed on two wooden strips; in the
case of a joining cabinet surface, remember to leave a space
of at least 45 x 560 mm at the back.

560 mm.

45 mm.

Summary of Contents for GC640

Page 1: ...in mind to try out new dishes effortlessly It also has 15 recipes preprogrammed into the oven so thanks to the interactive display once you have done the preparation all you have to do is make one si...

Page 2: ...er Retention of this Instruction Book This Instruction Book must be kept handy for reference as it contains important details on the safe and proper use of the appliance If you sell or pass the applia...

Page 3: ...y installed This appliance conforms with the following European Economic Community directives 73 23 EEC of 19 02 73 Low Voltage and subsequent modifications 89 336 EEC of 03 05 89 Electromagnetic Comp...

Page 4: ...d containers in or on the appliance or in cabinets immediately above or next to the appliance use flammable or plastic items on or near the hob use adapters multiple sockets and or extension leads fil...

Page 5: ...Off High Low Models fitted with an ignitor D the N L M P O Q symbolislocated near each knob To light a burner simply press the corresponding knob all the way in and then turn it in the counter clockwi...

Page 6: ...and problem persists call Hotpoint Service see KEY CONTACTS back page informing them of The type of problem The abbreviation used to identify the model Mod as indicated on the warranty IMPORTANT Never...

Page 7: ...next to cabinets provided the height does not exceed that of the hob For a correct installation of the cooking hob the following precautions must be followed a The hob may be located in a kitchen a ki...

Page 8: ...ent safety codes The maximum length of the flexible pipes must not exceed 2000 mm Once the connection has been made ensure that the flexible metal tube does not touch any moving parts and is not crush...

Page 9: ...and that of safety to ensure compliance with the law In the UK CORGI registered installers work to a safe standard of practice The hob must be installed in accordance with BS6172 Failure to install t...

Page 10: ...oker has been installed N B do not use reducers adapters or shunts as these could cause heating or burning Connection n 2 Disposing of the plug WARNING THIS APPLIANCE MUST BE EARTHED Ensure that befor...

Page 11: ...rs All repairs include a parts and labour guarantee for 12 months from the date of the repair If you require any information or have any questions about your appliance our operators are on hand with h...

Page 12: ...t to the following provisions that your appliance Has been installed and used correctly in accordance with this instruction booklet Has been used solely for domestic purposes and is located on domesti...

Page 13: ...entre co uk Republic of Ireland 1850 302 200 Note Our operators will require the following information Model number Serial number Extended Warranties UK 08709 088 088 Open 8 to 8 Mon Sun www theservic...

Reviews: