Indesit

 

Company

English

HEALTH AND SAFETY

For the servicing of refrigeration products, containing Isobutane R600a refrigerant.
These instructions are in addition to any other Company procedures already published.

Published primarily for Indesit Company engineers working in the UK or Southern Ireland, for 
which these instructions are MANDATORY.

1.

Only engineers who have been trained on the safe handling of Isobutane R600a refrigerant are 
authorised to transport, store or carry out system repairs.

2.

This manual is not intended as a comprehensive repair/maintenance guide to the appliance.

3.

Must only be used by suitably qualified persons having technical competence, applicable product 
knowledge, suitable tools and test equipment.

4.

Servicing of electrical appliances must be undertaken with the appliance disconnected (unplugged 
from the electrical supply).

5.

Servicing must be preceded by earth continuity and insulation checks, plus refrigerant leak
detection.

6.

Personal safety precautions must be taken to protect against accidents caused by sharp edges on 
metal and plastic parts.

7.

After servicing, the appliance must be rechecked for electrical safety.

8.

Smoking, naked flames, or operating gas and/or electrical equipment (including cordless power 
tools) are forbidden within the storage area, working area and vehicles used to transport Isobutane.

9.

The carrying case for the scales and refrigerant must display a red flammability label
Part Number C00247960 (8100063) that should be visible and readable at all times.

10. The vehicle and storage area must be ventilated as far as is reasonably practicable and the 

aluminium case kept out of direct sunlight. The storage temperature of Isobutane should not exceed 
50°C.

11. Vehicles carrying R600a canisters:

The Carriage of Dangerous Goods and Use of Transportable Pressure Equipment Regulations 2009 
(CDG 2009) require every transport unit to be equipped with one portable fire extinguisher, Part 
Number C00274640, for inflammability classes 

1

 A, B and C, with a minimum capacity of 2 kg dry 

powder.

12. The vehicle transporting Isobutane (R600a) refrigerant must display a Red Flammable Gas warning 

sticker (Part No. C00247960 [(8100063)].

13. Engineers should not wear clothes that are liable to cause static discharge ('electrostatic sparking').

14. Avoid working in small rooms.

15. Do not work in cellars.

16. Whenever possible move the appliance into a larger open area away from possible ignition sources.

17. Request the customer to turn off all other electrical and gas appliances in the near vicinity of the 

repair and note that it is done. 
Customers should be advised to restrict activity within the near vicinity for a short time.

18. Isobutane refrigerant must be vented to atmosphere, (outside of the premises e.g. via open window 

through the clear plastic hose supplied).

continued...

Summary of Contents for FFLAA58WDG

Page 1: ...terborough PE2 9JB Registered in London 106725 Service Information HOTPOINT FREESTANDING PARTIAL FROST FREE FRIDGE FREEZERS Models Comm Covered Code FFLAA58WDW 86522 FFLAA58WDG 86525 FFLAA58WDK 86670 5407927 Issue 1 June 2016 SM032033 C00384575 ...

Page 2: ...a working area and vehicles used to transport Isobutane 9 The carrying case for the scales and refrigerant must display a red flammability label Part Number C00247960 8100063 that should be visible and readable at all times 10 The vehicle and storage area must be ventilated as far as is reasonably practicable and the aluminium case kept out of direct sunlight The storage temperature of Isobutane s...

Page 3: ...No C00089700 2 Canisters must be stored inside the aluminium case with the weighing scales for protection from possible damage and heat The aluminium case must NEVER be placed next to a heat source or in direct sunlight 3 Isobutane must only be dispensed to the appliance from the 1kg net aluminium canister placed in an upright position on the weighing scales provided 4 All used canisters must be a...

Page 4: ...20 240 V 50 Hz 150 W W Fuse A Max 15 w Total Gross Bruto Brut Compr Kompr Syst R 134 a kg 0 090 Gross Bruto Brut 340 Net Util Utile Gross Bruto Brut Freez Capac Poder de Cong 75 Made in 13918 Test P S I Pressure HIGH 235 LOW 140 kg 24 h 4 0 Class Clase N Classe 1 2 Example 1 Industrial Code 93 13918 0000 0000 original production Commercial Code Factory of origin 2 Serial Number 7 04 1801 Build num...

Page 5: ...Refer to the Defrost wiring section for more information Note Defrosting is automatic Fridge Residual Air Wet Wall Freezer Heated Defrost No Frost The model has two adjustable front feet are adjustable with 2 fixed rear rollers as part of the base The climate class is N ST signifying that it is designed to operate in ambient temperatures between 16 C to 43 C As with many refrigeration appliances i...

Page 6: ...ºC Rating plate Refrigeration Type Freezer No Frost Fin On Tube FOT Evaporator Fridge Wet Wall Evaporator DIMENSIONS WEIGHT Height 1845 mm Width 545 mm Depth 595 mm Weight Gross 67 8 kg Weight Net 62 2 kg CAPACITIES VOLUME Fridge Freezer Net 178 litres 81 litres Freezing Capacities 4 Kg over 24 hours Conservation Time 19 5 hours Star Rating 4 Star TECHNICAL DATA Power Supply Voltage 220 240 volts ...

Page 7: ...le HEATER RESISTANCES Ω Evaporator Defrost Heater 638 Ω Defrost Timer Motor 27 KΩ Thermal Fuse 72 C one shot DEFROST TIMER Electromechanical TMDJX06ZR1 Black body type 250V AC 50 60 Hz DEFROST THERMOSTAT for Evaporator Defrost Heater 240 Volt AC Open circuit temperature 16 C approximate Closed circuit temperature 22 C approximate ONE SHOT FUSE for Evaporator Defrost Heater Open circuit temperature...

Page 8: ...IPTION TEMPERATURE CONTROL HOUSING APPLIANCE INTERIOR Thermostat Control with On Off switch LED Light Box Cover Fridge Vegetable Vegetable Commodity Racks Bottle Freezer Drawers Adjustable Front Feet 2 Control Box Shelves Box Shelf Reversible Doors Water Dispenser ...

Page 9: ...ach End Cap hole into the door screw hole and tighten securely Once secured clip the screw covers over the End cap moulding Screw Cover Handle End Cap Handle Bar Unclip the Screw Cover from the Handle End Cap Arrows show clip locations Screw Cover DOOR SIDE REAR VIEW screw cover removed OUTSIDE VIEW screw cover removed Screw Cover Handle shown screwed to the door Attach the screw cover over the ha...

Page 10: ...ry lean the appliance back at an angle not horizontal to allow access to the 3 bolts securing the bottom hinge bracket Remove the 3 screws securing the hinge and transfer it to the opposite side and tighten the bolts Note that only 3 of the 4 holes are used in the bracket The holes used differ depending on which side of the appliance it is fitted to When correctly fitted hinge pin will be aligned ...

Page 11: ...ŵƐ ĂƉĂĐŝƚŽƌ с ϯ ϱ Ƶ ŽŵƉƌĞƐƐŽƌ dLJƉĞ с D ŶŚƵŝ DĞŝnjŚŝ W ϴϬ ϭz Wd с YW ϮͲ ϭϱD ϯ ŽŵƉƌĞƐƐŽƌ KǀĞƌůŽĂĚ с Z ϭϯEϲϭ ϭ Thermostat KŶ Kī Thermal use ϳϯ Defrost Eǀaporator Heater ϯϬϬ ŽŚŵƐ Eǀaporator an Motor Defrost Timer Compressor KǀĞƌůŽĂĚ CapaĐitor PTC Start ĞǀŝĐĞ Light SwitĐh N с ϰ tĂLJ ŽŶŶĞĐƚŽƌ ĂƩĂĐŚĞĚ ƚŽ DĂŝŶƐ ĂďůĞ Blue to Compressor ĞŵĂůĞ ŽŶŶĞĐƚŽƌ Ͳ ǀŝĞǁ ĨƌŽŵ ƐŽĐŬĞƚ ƐŝĚĞ White to O L White to Defrost dŝŵĞ...

Page 12: ... LED Door Switch Compressor Over Load Compressor Capacitor PTC Start Device When the freezer temperature is lower than 22 C and the Timer switches to Defrost 1 2 the Defrost Heater is powered to start the defrost of the evaporator and the compressor stops The Timer stops because its Neutral terminal 3 is now the same potential as its Live terminal 1 When the freezer thermostat opens because the ev...

Page 13: ... EARTH DEFROST HEATER DEFROST THERMOSTAT THERMAL FUSE Chassis Earth Neutral via Male 4 way plug Timer Terminal 2 Defrost Timer 3 Live from Defrost Timer 4 Live to Compressor Overload via Male 4 way plug Rear Wall Connector Block Plug positions Rear Wall Connector Block Internal Wiring ...

Page 14: ... slide downwards to remove B Removing the Fridge Door 1 Remove the freezer door as in A1 to A3 2 Remove centre hinge and spacer if fitted Slightly open the fridge door and slide downwards to remove C Thermostat Removal 1 Pull off the Control Knob 2 Carefully prise the Fridge Light perspex lower edge from the lower edge of the housing with a flat bladed screw driver Fig 1 3 Unscrew the front and re...

Page 15: ...Assembly 1 Remove 2 screws from the Upper Fan Cover and lift it off Fig 3 2 Remove 4 screws from the Rear Duct Assembly Fig 4 and carefully lower it to gain access to the fan connector plug on the rear wall of the freezer 3 Unplug the fan wiring connector 4 Pull the plastic fan impeller off the motor shaft 5 The motor is held in place by a plastic bracket Release the bracket by unclipping both sid...

Page 16: ...e the timer from the bracket Make sure that the 2 clear rubber washer located between the timer and bracket are refitted during reassmbly Do NOT overtighten the screws 3 Cut 2 cable ties from the black plastic sleeve covering the connector plug 4 Unplug the timer from the harness 5 When reconnecting make sure that the plastic sleeve is fitted covering the plug and socket and secured tightly with a...

Page 17: ...m the black plastic sleeve covering the connector plug 4 When refitting make sure that the plastic sleeve is fitted covering the plug and socket and secured tightly with a cable tie round each end to prevent moisture ingress J Defrost Heater Evaporator 1 Remove the Rear Duct Assembly as in F above 2 Unplug the Heater connector from the connector block on the rear wall of the freezer 3 If necessary...

Page 18: ...18 of 18 Indesit Company Service Manual UK English END ...

Reviews: