8
GB
!
The installer must ensure that the correct electrical
connection has been performed and that it is fully compliant
with safety regulations.
Before connecting the appliance to the power supply, make
sure that
• The appliance is earthed and the plug is compliant with
the law.
• The socket can withstand the maximum power of the
appliance, which is indicated on the data plate.
• The voltage is in the range between the values indicated
on the data plate.
• The socket is compatible with the plug of the appliance.
If the socket is incompatible with the plug, ask an
authorised technician to replace it. Do not use extension
cords or multiple sockets.
!
Once the appliance has been installed, the power supply
cable and the electrical socket must be easily accessible.
!
The cable must not be bent or compressed.
!
The cable must be checked regularly and replaced by
authorised technicians only (see Assistance).
!
The manufacturer declines any liability should these
safety measures not be observed.
Gas connection
The appliance should be connected to the main gas supply
or to a gas cylinder in compliance with current National
regulations. Before carrying out the connection, make sure
the cooker is compatible with the gas supply you wish to
use. If this is not the case, follow the instructions indicated
in the paragraph “Adapting to different types of gas.”
When using liquid gas from a cylinder, install a pressure
regulator that complies with current National regulations.
!
Check that the pressure of the gas supply is consistent
with the values indicated in Table 1 (“Burner and nozzle
specifications”) since this will ensure the safe operation
and longevity of your appliance while maintaining efficient
energy consumption.
!
Should you need to install a gas hob on top of a built-in gas
oven, it is strictly forbidden to connect the two or to use a
single cut-off tap. The two appliances should be connected
separately, and each one should have its own stop tap
in order to make them completely independent from one
another (see figures).
NO
OK
Connection with a rigid pipe (copper or steel)
!
Connection to the gas system must be carried out in such a
way as not to place any strain of any kind on the appliance.
There is an adjustable
L
-shaped pipe fitting on the appliance
supply ramp and this is fitted with a seal in order to prevent
leaks. The seal must always be replaced after rotating the
pipe fitting (the seal is provided with the appliance).
The gas supply pipe fitting is a threaded 1/2 gas cylindrical
male attachment.
Connecting a flexible jointless stainless steel pipe to
a threaded attachment
The gas supply pipe fitting is a threaded 1/2 gas cylindrical
male attachment. These pipes must be installed so that
they are never longer than 2000 mm when fully extended.
Once connection has been carried out, make sure that the
flexible metal pipe does not touch any moving parts and is
not compressed.
!
Only use pipes and seals that comply with current National
regulations.
Checking the tightness of the connection
!
When installation has been completed, check the pipe
fittings for leaks using a soapy solution. Never use a flame.
DATA PLATE
Dimensions
width 43.5 cm
height 31 cm
depth 43.5 cm
Volume
58 l
This appliance conforms to the
following European Economic
Community directives:
2006/95/EEC dated 12/12/06
(Low Voltage) and subsequent
amendments - 2004/108/EEC
dated 15/12/04 (Electromagnetic
compatibility) and subsequent
amendments - 93/68/EEC dated
22/07/93 and subsequent
amendments. 2009/142/EEC
dated 30/11/09 (Gas) and
subsequent amendments.
2012/19/EC and subsequent
amendments.
Summary of Contents for FH G /HA
Page 3: ...3 8 8...
Page 22: ...22 AR...
Page 23: ...AR 23...
Page 24: ...24 AR...
Page 25: ...AR 25...
Page 26: ...26 AR...
Page 27: ...AR 27...
Page 28: ...28 AR...
Page 29: ...AR 29...
Page 30: ...30 AR...
Page 31: ...AR 31...