ERROR CODES & POSSIBLE CAUSES
When an error occurs the following LEDs will flash indicating a fault.
Refer to the chart below for the error code definitions.
FAULT
LED COMBINATION
LED 5
LED 4
LED 3
LED 2
LED 1
F01
Off
Off
Off
Off
On
F02
Off
Off
Off
On
Off
F03
Off
Off
Off
On
On
F04
Off
Off
On
Off
Off
F05
Off
Off
On
Off
On
F06
Off
Off
On
On
Off
F07
Off
Off
On
On
On
F08
Off
On
Off
Off
Off
F09
Off
On
Off
Off
On
F10
Off
On
Off
On
Off
F11
Off
On
Off
On
On
F12
Off
On
On
Off
Off
F13
Off
On
On
Off
On
F14
Off
On
On
On
Off
F15
Off
On
On
On
On
F16
On
Off
Off
Off
Off
F17
On
Off
Off
Off
On
F18
On
Off
Off
On
Off
F01
Motor triac short circuit:
Check motor and module
connections
F02
Motor jammed / tacho detached:
Check motor and module connections
F03
NTC short/open circuit:
Check thermistor and module connections
F04
Pressure switch jammed on empty:
Check switch and module
F05
Pressure switch jammed on full or pump blocked:
Check pump and switch
F06
N/A
F07
Heater relay stuck:
Check heater and module connections
F08
Heater relay stuck:
Check pressure switch, heater and module connections
F09
Setup error:
Check Eeprom
F10
Pressure switch not sensing:
Check switch and module connections
F11
Pump cannot be activated:
Check pump, connections and wiring
F12
No communication between cards:
Check module connections
F13
High temperature Rise In Drying: Reduced air flow through dryer heater
assembly.
Check operation of fan motor and dryer filter for blockage
F14
No Heat In Drying:
Check one shot thermostat. Check heater, valve and fan
motor module connections. Edge connector J10
F15
No Drying:
Possibly dryer relay open circuit
F16
N/A
F17
Door lock error:
Check door, door lock and module connections
F18
Communication error (3 phase motor):
Replace power board
LED 1
LED 2
LED 3
LED 4
LED 5