background image

� 

Operation and  Setup 

Working  Parameters Display 

Battery Type-string Number 

Current & Completion 

--� 

Percentage 

Task Status 

Present 

Current 

Capacity 

Charged 

Operation Time 

Present 

---

Power 

Current Total 

Battery 

Voltage 

3.999V 

3.994V 

3.998V 

3.996V 

3.gg7

___ 

Cell Voltage

3.995V 

Discharging 

Discharging Status Simple Operation 

1. Connect power supply to the AC or DC port of the charger, wait for the system

to complete the self-checking.  connect the battery to the charger in the standby interface;

2. In the standby state, short press Okey to pop up the  "Task Settings"  menu, set the

task to  "Discharge"  , adjust the task parameters, and short press O key to start the task;

Press /\ key or V key during operation can switch the display information in the lower half of the screen,

which are cell voltage and run data,  the cell voltage and internal resistance can only be displayed in the

mode of balance charging.

3. When the discharge task is executing,  short press the O key to pop up the  "Adjust

Task"  menu,  will adjust the discharge current,  long press the O key can stop the

current task;

4. Enjoy.

-

HGT.; 

HG  PRO AC/DC Smart Charger

Summary of Contents for H6 PRO

Page 1: ... 1111111111 nu H6 PRO AC DC Smart Charger Operating Instructions Shenzhen HOTA Technology Co LTD ...

Page 2: ...es of smart chargers Please read this Instructions carefully before use so as to use the product better please keep this Instruction in a place safe for easy access If you want to know more about our smart chargers please visit our website www hota exp com Ver 2 0 2 ...

Page 3: ...Parameters 06 Operation and Setup 01 1 How to Confirm Charging Current 07 2 Operative Skills 07 3 Working Parameters Display 08 4 Charger Settings 17 5 Charger Settings Task Parameters 18 6 Charger Settings System Parameters 19 7 Charger Settings Tools 20 8 Task Settings 21 9 Task settings and Notes 22 Product Qualification Declaration 26 Troubleshooting 21 Warranty and service 21 Safety Tips 28 S...

Page 4: ...W unique regenerative discharge capability Regenerative discharge takes most of the output battery s energy and puts it back into the input battery in a balance way IPS Display New Simple UI The 2 4 inches 260000 colors IPS display with the new simple UI gives you a delightful experience Intelligent Upgrade Fast Experience Built in Micro USB connector for a much easier and faster firmware upgrade ...

Page 5: ...r External Discharge 700W Operating 0 40 C Temperature Screen Size 2 4 IPS 320x240 LiHV LiPo LiFe Lilon Lixx 1 6S 260000 colors NiZn NiCd NiMH 1 14S Battery Smart Battery 1 6S Dimensions 108mmx67mmx60mm Type Lead Acid Pb 1 12S 2 24V Eneloop 1 14S Net Weight 410g Protection Temperature protection time protection capacityprotection input reverse Function protection output protection short circuit pr...

Page 6: ... Product Overview Introduction Update Port AC Port v So eot DC Port ____ Touch Key e USB Port SV Balance Port Battery Port Multi Function Port HGT I H6 PRO AC DC Smart Charger ...

Page 7: ...e charger 5 Make sure the heat emission hole at the side of the charger is uncovered while in use and ensure the cooling fan smoothly extracts heat 6 Please fully understand the charging and discharging characteristics as well as the battery s specifications Additionally set up proper charging parameters in the charger Incorrect setting of parameters can cause damage to the charger and battery and...

Page 8: ...Port Connection and Notes 1 The detection balance port of this product is suitable for lithium battery packs 2 When the battery is connected it is aligned with the sign The diagram above shows the alignment of the balance plug HGT I H6 PRO AC DC Smart Charger ...

Page 9: ...ane control servo 2 Connect to the RC airplane receiver or RF transmiter s I I I _ s RC airplane control servo connects to the multi function port s I I I _ s RC airplane receiver or RF transmiter connects to the multi function port HGT I H6 PRO AC DC Smart Charger ...

Page 10: ... supported supported supported supported supported supported supported supported supported Unbalanced supported supported supported supported supported supported supported supported supported supported Charge Support 1 14S 1 6S 1 6S 1 6S 1 6S 1 14S 1 6S 1 6S 1 12S 1 14S Cells Max Charge 26 0A 26 0A 26 0A 26 0A 26 0A 26 0A 26 0A 26 0A 26 0A 26 0A Current Max Charge e2C e4C elC elC elC eQ SC elC elC...

Page 11: ...arging time 60 minutes charging C value it therefore needs around 60 70 minutes to complete charging with 1C Due to differences in battery conversion efficiency the period to complete the charging might be extended Operative Skills 1 Connect power supply to the charger s AC or DC port wait for the system to complete the self checking In standby interface connect the battery to the charger short Pr...

Page 12: ... connect the battery to the charger in the standby interface 2 The blue display in the standby state at this time the output current output power capacity charged and run time are all zero Press A key or V key during operation can switch the display information in the lower half of the screen which are cell voltage and run data 3 Short press Okey to pop up the Task Settings menu adjust task parame...

Page 13: ... checking connect the device that requires charging to the output of the charger in the standby interface 2 In the standby state short press Okey to pop up the Task Settings menu set the task to Power supply adjust the task parameters and short press Okey to start the task Information displayed in the lower half of the screen input voltage operating temperature input voltage charged times 3 Short ...

Page 14: ...andby interface 2 In the standby state short press Okey to pop up the Task Settings menu set the task to Charge adjust the task parameters and short press Okey to start the task Press key or v key during operation can switch the display information in the lower half of the screen which are cell voltage cell internal resistance and run data the cell voltage and internal resistance can only be displ...

Page 15: ...198V 0 4 193V 8 4 195V 0 4 198V Fast Charge Done Fast Charge Done Status Simple Operation Present Power Current Total Battery Voltage Cell Voltage 1 When charging is completed the cell voltage difference is less than 20mV displayed fast charge Done press the O key to stop the task before removing the battery 2 Short press the O key can stop the current task HGT I HG PRO AC DC Smart Charger ...

Page 16: ...ery to the charger in the standby interface 2 In the standby state short press Okey to pop up the Task Settings menu set the task to Discharge adjust the task parameters and short press Okey to start the task Press key or V key during operation can switch the display information in the lower half of the screen which are cell voltage and run data the cell voltage and internal resistance can only be...

Page 17: ...ischarge to the input ends DC port of the charger and wait for the system to complete its self checking then in the standby interface connect the high power resistance load to the charger s output ends 2 In the standby state short press Okey to pop up the Task Settings menu set the task to Ext discharge adjust the task parameters and short press Okey to start the task 3 When the Ext discharge task...

Page 18: ...he battery to the charger in the standby interface 2 In the standby state short press Okey to pop up the Task Settings menu set the task to Storage adjust the task parameters and short press Okey to start the task Press I key or V key during operation can switch the display information in the lower half of the screen which are cell voltage and run data the cell voltage and internal resistance can ...

Page 19: ...ry to the charger in the standby interface 2 In the standby state short press Okey to pop up the Task Settings menu set the task to Balance adjust the task parameters and short press Okey to start the task Press key or V key during operation can switch the display information in the lower half of the screen which are cell voltage and run data the cell voltage and internal resistance can only be di...

Page 20: ...ery to the output of the charger in the standby interface 2 In the standby state short press Okey to pop up the Task Settings menu set the task to ReGen Discharge adjust the task parameters and short press Okey to start the task Press key or V key during operation can switch the display information in the lower half of the screen which are cell voltage and run data the cell voltage and internal re...

Page 21: ...djust Safety Timer Max Capacity End Current and other parameters System Parameters Adjust Language Regen Discharge input power Volume and other parameters Tools For PWM measurement Servo Test PPM Out Calibrations For data calibration System Self checking Start self checking of the charger Factory Settings Restore all parameters to factory settings User calibration data cleanup System Info Display ...

Page 22: ...em the menu items are as follows Safety Timer Allows maximum running time running beyond this setting automatic protection will stop the task Max Capacity Allows maximum charging capacity running beyond this setting automatic protection will stop the task End Current Cut off when less than the ratio between completed current and set up current Trickle Charge Whether to turn on trickle charge On or...

Page 23: ...ws Language System language setting Regen Discharge Set Current Voltage and Power Max input power Input power limit setting Min input voltage Input voltage limit setting LCD backlight Backlight adjustment high middle low Volume Buzzer volume adjustment high middle low Completion Signal Single or Repeat Device Name Up or down button to choose letter enter the device name manually long press the O k...

Page 24: ...hannels Back Back to theupper menu PWM Measurement The RC airplane control servo signal is analyzed by the PWM protocol the signal output of the RC receiver is connected and the signal period and pulse width of the PWM output are automatically detected then converted into the steering output shaft rotation angle value Servo Test The RF airplane PWM protocol is directly connected to the servo throu...

Page 25: ...enu the menu items are as follows Select task Select task content Power supply Charge Discharge External discharge Storage Balance ReGen discharge Battery type Selectbattery types Smart battery LiHV LiPo Lilon LiFe LiXX NiZn Pb NiCd NiMH Eneloop Cell voltage End voltage slight adjustment Cell count Select battery s strings 1 6S ifbalance port is inserted then it processes automatic test no need to...

Page 26: ... is less than 20m and the screen turns green If you need to use it urgently you can stop charging it If charging is not stopped at this time the charger will continue to balance the battery When the voltage difference is less than 1 0mV the screen will turn blue When turned blue the charger will continue to accurately balance the battery After having the battery charged the voltage will drop back ...

Page 27: ...ll be automatically performed if the battery voltage is higher than the preset storage voltage the discharge task will be automatically performed In order to save the task time the storage and discharge tasks do not accurately balance the cell voltage There may be some error between the cell voltage and the presetvalue at the end of the task which is a normal phenomenon Balance Function The balanc...

Page 28: ... to the charger s output port and set the task to regeneration discharge on the charger to discharge and recycle for lithium battery it is strongly recommended to connect to the balance port of the charger for balanced discharge Input Port Battery Activation And Repair After the charging task starts if it is detected that the cell voltage is lower than the pre charging voltage the cell will be act...

Page 29: ...rent is instantaneously adjusted Therefore it is normal to find that the current is abruptly changed during the charging process Due to the difference in the ways of measuring the internal resistance the test accuracy of internal resistance like those attained on professional measuring instruments cannot be achieved Therefore the internal resistance value is only suitable for horizontal comparison...

Page 30: ...commands in B 2017 PART15 CLASSB PART15 CLASSC FCC Testing Standards EN 60950 1 2006 A11 2009 A1 2010 A12 2011 A2 2013 EN 62311 2008 ETSI EN 301 489 1 V2 2 0 2017 03 ETSI EN 301 489 3 V2 1 1 2017 03 ETSI EN 303 417 V1 1 1 2017 09 HGT I H6 PRO AC DC Smart Charger Result Yes Yes Yes Yes ...

Page 31: ...tact Warranty and Service We provide one year warranty for this charger from the date of purchase Within one year our company will repair the product for you free of charge We will not provide free repair service if it is caused by improper use or modification by customers If there is a problem with your product and it is covered by the warranty please contact us at the first time we will assist y...

Page 32: ...hold waste when handling scrapped products Take it to the garbage collection center for classification Statement The H6 PRO AC DC Smart Charger is designed for the battery types listed in this Instructions The company does not assume any responsibility if the user uses the charger for purposes other than those listed in the Instructions We are not sure if you have read the instructions carefully b...

Page 33: ...ects during use Do not charge or discharge on the carpet paper plastic products vinyl leather wood or charge or discharge inside the aircraft model or inside the car Do not place the charger within reach of children Do not drop wires or other conductive objects into the charger Ensure that the battery type and parameters are selected correctly If you choose the wrong one it may not only damage the...

Page 34: ...ll tt M lfflU a J nu Shenzhen HOTA Technology Co LTD Add Floor 2 Building 2 Guorun Industrial Park Min Zhi Longhua District Shenzhen China Tel 0755 28180135 Website www hota exp com E mail info hota exp com ...

Reviews: