![Hot Shot 810-R Plus Manual Download Page 5](http://html1.mh-extra.com/html/hot-shot/810-r-plus/810-r-plus_manual_2165715005.webp)
5
BASIC MULTIPLE PUMP OR RELAY CONTROL WIRING DIAGRAM
USING 1 HOT SHOT 810-R PLUS TO CONTROL UP TO 6 PUMPS OR RELAYS.
This style of receiver is convenient when the pumps or relays are located close together or when their power sup-
ply comes from the same circuit box. This will save money and time in eliminating the need for extra receivers at
each relay. See diagram below.
JUMPER WIRE
WELL #1
WELL #2
WELL #3
USING THE MULTIPLE RELAY OUTPUT TERMINALS
When a Hot Shot Receiver 810-R PLUS is going to be used with a
Hot Shot 810-T transmitter using it’s #1,2,3,4,5, OR 6 SENSOR
INPUT or the Pump Selector Kit the receiver’s going to be used will
need to use the corresponding transmitter SENSOR INPUT termi-
nals to control the pump or relay outputs accordingly. The #1 Sen-
sor Input on the transmitter will only turn ON and OFF the #1 Relay
Terminals on the receiver. The same goes for the #2 Sensor Input on
the transmitter will only turn ON and OFF the #2 Relay Terminals
on the receiver and so on for all the sensor inputs and corresponding
relay outputs. The picture shows the layout of the Relay Terminals
on the 810-R PLUS receiver.
#1
RELAY
#2
RELAY
#3
RELAY
#6
RELAY
#5
RELAY
#4
RELAY
JUMPER WIRE
WELL #4
WELL #5
WELL #6