ENGINE STARTUP MODE 

With function switch 6 on turn on the power to the receiver to enable the Engine Startup Mode.  When activated the Supervi-
sion LED will come on and bypass the Murphy switch to allow the engine to start and stay running until the transmitter has sent 
its relay ON command to the receiver thus ending the bypass timer and taking control of the receiver and turning off the Super-
vision LED.  If the transmitter has not sent the relay ON command within 15 min the receiver will kill the engine and you will 
have to turn the receiver off and then back on again to get it into Engine Startup Mode again.

 

SUPERVISION FEATURE

 

The Supervision Feature is a great way for checking at a glance the integrity of communications between the transmitter and 
receivers.  The supervision feature is designed to work with only one transmitter per system as the supervision feature’s timer 
can operate on multiple receivers at the same time.  When function 9 (Refresh) is turned on in the transmitter, it will send out a 
check-in signal 

(technically it’s a command telling each receiver on the system to reset it’s supervision timer, i.e. system is 

working properly

) every 45 minutes.  If the check-in signal is not heard by the receiver before the internal supervision timer 

expires, due to transmitter or receiver issues, the receiver will then look at its function switches (7, 8 or 9) and take the selected 
course of supervision action. See below. 

FAIL-SAFE OPERATION 

RELAY 1 OUTPUT ONLY

 

This feature works with the Supervision 
feature as described above but lets us 
take safety a step further.  Fail-Safe 
mode allows the receiver to control the 
#1 internal relay by activating or deacti-
vating itself if the transmitter is not 
working properly.   

 

SCENARIO 1 

Turning on Function switch 7 

will 

make the receiver’s internal #1 relay 
energize if there is a system failure 
(closing N.O. to COM.). 

 

SCENARIO 2 

Turning on Function Switch 9 

will 

make the receiver’s internal #1 relay de-
energize if there is a system failure  
(closing N.C. to COM.). 
 

LOAD SHARING 

Different delay times on the receivers 
can help with large electrical current 
pulls in the same field on start up. 

SWITCH# 

FUNCTION SWITCH SETTINGS 

FOR RELAY #1 OUTPUT ONLY 

ON

  

WILL ACTIVATE MOMENTARY FOR 10 SEC.   

 

 

 

 

 

ON

 

INVERTED RELAY OUTPUT CONTROL 

 

 

 

 

 

ON

  

ACTIVATION OF RELAY DELAYED BY 10 SEC. 

(See Load Sharing below

 

4

 

ON

 

ACTIVATION OF RELAY DELAYED BY 5 SEC.   (

See Load Sharing below

 

NOT USED 

 

 

 

 

 

 

 

 

 

6

 

ON 

ACTIVATES ENIGNE STARTUP MODE - WITH 15MIN BY-PASS TIMER (

See below) 

 

 

7

 

ON

 

ACTIVATES FAIL-SAFE MODE - SCENERIO 1 

(

See FAIL-SAFE OPERTAION below

)

 

 

ON

 

ACTIVATES THE SUPERVISION MODE - LED ONLY.  

 

 

 

ON 

ACTIVATES FAIL-SAFE MODE - SCENERIO 2 

(

See FAIL-SAFE OPERTAION below

)

 

Summary of Contents for 810-R Plus

Page 1: ... ELECTRIC WELL 7 RECEIVER HOOKUP TO ELECTRIC WELL DIAGRAM 8 RECEIVER HOOKUP TO ENGINE DRIVEN WELL Version 1006 Hot Shot Systems Inc will no longer sell or warranty its products for the use in controlling or monitoring pollut ants However the use of these controllers in non pollutant applications such as water tanks water pumps pivots irrigation systems and any other monitoring or control applicati...

Page 2: ...modifications not expressly approved by the party re sponsible for compliance could void the user s authority to operate the equipment HOW IT WORKS Think of the HOT SHOT system as a control wire going from the transmitter site to the receiver site When the Hot Shot Transmitter s SENSOR ON OFF Input is connected to COM a 10 second delay timer is started After the delay timer has expired the transmi...

Page 3: ...KEY to the left to make each digit of the code It takes three of the switches to make one num ber of the code Use switches 1 2 3 for the first in the code Switches 4 5 6 for the second Switches 7 8 9 for the third Switches 10 11 12 for the fourth Transmitter Code Switches INDICATOR LEDS POWER Signals that the Receiver has power and is ready to receive the code from the Transmitter STROBE Used for ...

Page 4: ... the internal supervision timer expires due to transmitter or receiver issues the receiver will then look at its function switches 7 8 or 9 and take the selected course of supervision action See below FAIL SAFE OPERATION RELAY 1 OUTPUT ONLY This feature works with the Supervision feature as described above but lets us take safety a step further Fail Safe mode allows the receiver to control the 1 i...

Page 5: ...d with a Hot Shot 810 T transmitter using it s 1 2 3 4 5 OR 6 SENSOR INPUT or the Pump Selector Kit the receiver s going to be used will need to use the corresponding transmitter SENSOR INPUT termi nals to control the pump or relay outputs accordingly The 1 Sen sor Input on the transmitter will only turn ON and OFF the 1 Relay Terminals on the receiver The same goes for the 2 Sensor Input on the t...

Page 6: ...ire the 120v X2 terminal of the step down transformer to the neutral 120vac input of the Hot Shot Receiver see diagram on the next page Add a jumper from the first 120vac terminal to the Hot Shot Receivers relay COM terminal see diagram on the next page Wire the NO terminal on the Hot Shot Receiver to one side of the 120v relay coil Connect the other side of the relay coil to the X2 terminal of th...

Page 7: ... ON SIGNAL IT WILL CLOSE ITS N O TO COMMON CONTACTS THIS WILL ENERGIZE THE 120V RELAY TO CLOSE THE 480V CONTACTOR ELECTRIC WELL HOOKUP DIAGRAM W 3 RELAYS IN PARALLEL This diagram illustrates how to let an electric pump stay operating until all the transmitters have sent their turn off command It is a sim ple way of wiring all the receiver relays in parallel so that the pump stays operating until a...

Page 8: ...nnect a wire from the N C terminal on the Hot Shot receiver to the S or the SW1 terminal on the Murphy kill switch Turn on function switch 6 and turn on the power to the receiver to enable the Engine Startup Mode for details see pg 4 When activated the Supervision LED will come on and bypass the Murphy switch to allow the engine to start and stay running until the transmitter has sent its relay ON...

Page 9: ...ot has various lightning and static protection devices incorporated on the cir cuit board that require proper grounding to operate Any equipment or device panels operating with or near the Hot Shot should also be con nected to the grounding system A good ground will enhance the trans mit and receive range of the Hot Shot System GROUNDING PER NATIONAL ELECTRICAL CODE DEVICE PANEL ...

Page 10: ...g or losing power to the receiver Operational Note When using Fail Safe Scenario 1 the receiver s relay is energized and if power is lost while the receiver is in Fail Safe operation the receiver s relay will de energize When power is restored the re ceivers relay will not immediately go back into Fail Safe operation The receivers relay will remain de energized and the device it is controlling may...

Reviews: