![Hoshizaki WOX-40WA-EW Installation Manual Download Page 5](http://html1.mh-extra.com/html/hoshizaki/wox-40wa-ew/wox-40wa-ew_installation-manual_2165584005.webp)
4
6. REMOTE CONTROLLER (OPTION)
[a] CONNECTING HOSE TO REMOTE CABLE
1) Attach the optional plumbing parts to the back of the remote
controller.
2) Remove the four screws from both sides of the unit’s front panel.
Connect the remote cable.
3) Remove the sensor connector from the back of the front panel.
Bind the connector with the other leads.
Shut-off Valve
Water Supply Valve
Drain Valve
Dual Check Valve
(accessory)
Water Supply Pipe
Max. 50cm
Max. 1m
Drain
Salt Water Tank
Salt Water Hose
Suction Hook
(two)
Drain Hose (left, right)
Water Supply Inlet
(G3/4)
Example
Remote
Cable
Gasket
Union - Elbow
Hose Clamp
Braided Hose
Connector
Receptacle
Remote Controller
(Back)
Front Panel
Hose Clamp
Remote Cable
Screw (2 on
each side)
Put through
Remove
and bind
Remove grommet and
fix remote cable
Sensor
Connector
[b] INSTALLING REMOTE CONTROLLER
1) To attach the bracket provided for the remote controller, make
mounting holes in the wall according to the dimensions below, and
provide male thread type M6 cast-in anchor bolts or a sheet metal
depending on the installation site.
2) Install the remote controller on the bracket.
7
9
mm
96 mm
Mounting Dimensions
3) Connect the nozzle hose (accessory) to the water outlet using the
gasket provided for the remote controller.
Screw (2 pcs)
Screw (2 pcs)
Hook
Water Outlet
Gasket
Nozzle Hose
Pressure Reducing Valve (accessory)