Hoshizaki WOX-40WA-EW Installation Manual Download Page 5

4

6. REMOTE CONTROLLER (OPTION)

[a] CONNECTING HOSE TO REMOTE CABLE

1) Attach the optional plumbing parts to the back of the remote 

controller.

2) Remove the four screws from both sides of the unit’s front panel. 

Connect the remote cable.

3) Remove the sensor connector from the back of the front panel. 

Bind the connector with the other leads.

Shut-off Valve

Water Supply Valve

Drain Valve

Dual Check Valve

(accessory)

Water Supply Pipe

Max. 50cm

Max. 1m

Drain

Salt Water Tank

Salt Water Hose

Suction Hook 

(two)

Drain Hose (left, right)

Water Supply Inlet 

(G3/4)

Example

Remote 

Cable

Gasket

Union - Elbow
Hose Clamp

Braided Hose

Connector

Receptacle

Remote Controller 

(Back)

Front Panel

Hose Clamp

Remote Cable

Screw (2 on 

each side)

Put through

Remove 

and bind

Remove grommet and 

fix remote cable

Sensor 

Connector

[b] INSTALLING REMOTE CONTROLLER

1) To attach the bracket provided for the remote controller, make 

mounting holes in the wall according to the dimensions below, and 

provide male thread type M6 cast-in anchor bolts or a sheet metal 

depending on the installation site.

2) Install the remote controller on the bracket.

7

9

mm

96 mm

Mounting Dimensions

3) Connect the nozzle hose (accessory) to the water outlet using the 

gasket provided for the remote controller.

Screw (2 pcs)

Screw (2 pcs)

Hook

Water Outlet

Gasket

Nozzle Hose

Pressure Reducing Valve (accessory)