FOR QUALIFIED INSTALLER ONLY
WOX-40WA-EW
WATER ELECTROLYZER
INSTALLATION MANUAL
L2X006112 (111520)
3-16 Minamiyakata, Sakae-cho, Toyoake, Aichi 470-1194 Japan
Page 1: ...FOR QUALIFIED INSTALLER ONLY WOX 40WA EW WATER ELECTROLYZER INSTALLATION MANUAL L2X006112 111520 3 16 Minamiyakata Sakae cho Toyoake Aichi 470 1194 Japan...
Page 2: ...r sanitizing and cleaning water lines Hydrogen gas or chlorine gas may cause health problems 1 CONSTRUCTION a EXTERIOR 7 Drain outlet left Drains sanitizing water in flush cycle 8 Salt water hose 9 Sa...
Page 3: ...he circuit is being flushed 4 Flush cell button Press this button to flush the electrolytic cell The red lamp flashes while the cell is being flushed 5 Sensor lamp blue Illuminates when the sensor det...
Page 4: ...ER SUPPLY LINE IMPORTANT 1 Use potable water only Use of non potable water may cause corrosion clogged pipes or health problems 2 The water supply pressure must be within 0 1 to 0 75 MPa 100 to 750 kP...
Page 5: ...Gasket Union Elbow Hose Clamp Braided Hose Connector Receptacle Remote Controller Back Front Panel Hose Clamp Remote Cable Screw 2 on each side Put through Remove and bind Remove grommet and fix remot...
Page 6: ...ual water hardness is not measured the unit regards the hardness as 200 mg L default setting resulting in a longer cell flush cycle If the display shows FAIL measure the hardness again after a trial r...
Page 7: ...ability under the terms of the warranty are limited and shall exclude routine servicing cleaning essential maintenance and or repairs occasioned by misuse and installations not in accordance with Hosh...