17
F. Electrical Connection
WARNING
1. Electrical connection must be made in accordance with the instructions on the
"WARNING" tag, provided with the pig tail leads in the condensing unit junction
box.
. Electrical connections must meet national, state and local electrical code
requirements. Failure to meet these code requirements could cause severe
injury to individuals or extensive damage to equipment.
3. Be sure to install a ground to the icemaker unit and the condensing unit.
• Electrical connections must be installed in accordance with applicable national, state and
local regulations.
• Usually an electrical permit and services of a licensed electrician are required.
• Power to the icemaker unit is supplied by the condensing unit.
• For the wire harness connection, use appropriate outdoor-rated 18 AWG wire. See wiring
label for wiring connections.
1. Condensing Unit
1) Supply power from the panel to the condensing unit. (This differs from KM style
installations.)
) Connect the wire leads in the power supply junction box to the power supplied from the
disconnect or electrical panel.
Note: On single phase machines, the white lead must be attached to the neutral
conductor of the power source. Miswiring results in severe damage to the
icemaker. See Fig. 7. For three phase, see Fig. 8.
Fig. 7
WARNING
ELECTRICAL CONNECTION
The white lead must be connected
to the neutral conductor of the power
source.
Miswiring results in severe damage to
the icemaker.
(See Fig. below.)
08-30/60/1
(3 wire with neutral for 115V)
Power Supply
Junction Box
Brown
White
Black
L1
N
L
08-
30V
1
0-
1150V