26
1. Icemaker
• Icemaker water supply inlet is 1/2" female pipe thread (FPT). A minimum of
3/8" nominal ID copper water tubing or equivalent is required for the icemaker water
supply line.
• An icemaker water supply line shut-off valve and drain valve should be installed.
• Icemaker drain outlet is 3/4" FPT. A minimum of 3/4" nominal ID hard pipe or equivalent
is required for the icemaker drain line. Condensation drain outlet is 5/8" OD hard tube.
The condensation drain line can be connected to the icemaker drain line or can be run
separately.
Fig. 17
KMS-2000MLJ
Icemaker Water
Supply Inlet
1/2" FPT
Icemaker Water Supply
Line Shut-Off Valve
Icemaker Water Supply
Line Drain Valve
Icemaker Drain
Outlet 3/4" FPT
Icemaker Condensation
Drain Outlet
5/8" OD Hard Pipe
Bin Drain Outlet
3/4" FPT
Separate piping to approved drain.
Leave a 2-inch (5-cm) vertical air gap
between the end of each pipe and the
drain.
2-inch (5-cm)
air gap
Floor
Drain
Storage Bin
Icemaker
Vent Tube
Minimum 3/8" Nominal ID
Copper Water Tubing
Minimum 3/4" Nominal ID Hard Pipe