18
6) Slide the bin control assembly all the way back until the switch mount is flush with the
dispenser unit bin wall or the storage bin wall, top kit extension bracket, or brace. See
Fig. 11. Tighten the outer switch cover thumbscrews.
NOTICE
On dispenser unit applications, do not leave a gap between the bin control and the
wall of the dispenser unit bin wall. If a gap is left between the bin control and the
wall of the dispenser unit bin wall, ice may get between them and damage the bin
control.
Dispenser Unit:
Slide the bin control
assembly all the way back until the switch
mount is flush with the dispenser unit bin
wall.
Storage Bin:
Slide the bin control assembly
all the way back until the switch mount is
flush with the storage bin wall, extension
bracket, or brace.
Dispenser
Unit
Icemaker
Fig. 11
Switch Mount
Evaporator
Bin Control Cable
Cable Tie
To Control Box
Plastic Pipe
Hose
Fig. 12
7) Pull the bin control cable so that there is no slack in the ice drop area, then secure the
hose that the lead runs through with a cable tie. See Fig. 12.
8) Replace the water tank in the icemaker and reconnect the 4 hoses.
Note: Panels replaced during "II.I. Startup."