DISCONNECT UNIT FROM POWER SUPPLY BEFORE DOING ANY SERVICE
Instructions to Replace Condenser Fan Motor
11. Remove the bolt that hold in
place the fan blade to the fan
motor using a 9/32” socket
screwdriver.
12. Unscrew. the two screws that
hold in place the base motor to
the fan motor using a 9/32”
socket screwdriver.
13. To install the new condenser
fan motor reverse the previous
steps.