Instructions to Replace Compressor.
9 . The first step is to recover all refrigerant
from the system by installing a piercing
valve in the compressor service tube.
Attach the hose of the recovery
machine to the service tubing. Use an
Allen Key Wrench to close the piercing
valve for piercing the tube and open it
to release the refrigerant.
10. Open Manifold Gauge
Pressure valves and
turn on the recovery
machine to recover all
the refrigerant.
11. Warm the brazing of
the discharge and
suction tubes in
order to unsolder
them from the
compressor.
12. To remove the filter
dryer, slowly warm
up the joint of the
capillary tubing with
the filter dryer and
pull them apart by
using pliers.