DISCONNECT UNIT FROM POWER SUPPLY BEFORE DOING ANY SERVICE
Instructions to Replace Condenser Fan Motor
7. Disconnect the Tyco
electrical connector of
the condenser fan motor.
8. Unscrew the two screws
that hold in place the
base motor to the rails
using a Phillips
screwdriver # 2
5. Pull out the condensing
unit from the base of the
cabinet.
6. The condensing unit can
be removed all the way
out for easier service.