35
Refill
1. Float Switch
a) Dirty/sticking.
b) Defective.
2. Inlet Water Valve
a) Clogged or defective.
3. Water Supply
a) Off.
4. Control Board
a) No power to float switch or not reading float switch condition.
b) No power to inlet water valve.
Shutdown
1. Bin Control 1 (infrared sensor)
See "II.D. 1. Bin Control 1
(infrared sensor) Check."
a) Dirty lens.
b) Defective.
c) Control board (no power to IS).
2. Bin Control 2 (mechanical
backup)
See "II.D.2. Bin Control 2
(mechanical backup) Check."
a) Tripped with bin filled with ice (9-beep alarm).
b) Proximity switch defective.
c) Actuator paddle does not move freely.
d) Control board defective.
3. Control Board
a) Control board dip switches set incorrectly.
b) In alarm.
c) Defective.
Drain Cycle
1. Drain Valve
a) Screen or orifice clogged.
b) Defective.
2. Control Board
a) Defective.