Caution 

The Chiller is not suitable for use in subfreezing temperatures. 
To prevent damage to the water supply line, turn off and drain 
unit when air temperature is below zero. 

 

 

The Chiller should be located in a well-ventilated, firm, level location close to dispenser, water 

and electrical supplies, with easy access for servicing 

 

SPC version Chillers are intended for use in the bar area. 

 

SPK2-11 version chillers are intended for use in a non temp controlled storage area. 

 

Ensure sufficient clearance around Chiller to allow good fresh air circulation through the 

condenser – allow at least 200mm at rear, sides and top, with the front unobstructed. 

 

Installation should only be performed by a qualified and competent technician. 

6.4  

Mounting Chiller 

 

Install on a flat, level surface using adjustable legs or casters (Optional).  

 

Caution 

Chiller operational weight is 157/179kg; ensure that all 
supporting structures are certified for this loading by a 
registered Mechanical Engineer.  
Supporting structure must be securely fixed to floors or walls.

 

 

6.5  

Connecting Python 

Connect Python to Chiller and Dispenser. 

 

Caution 

NOTE: The Chiller is rated to operate with a maximum of 30m of 
python connected.  

Exceeding manufacturer’s ratings may cause damage to the 
Chiller and void warranty. 

 

Python Details 

Recirculation Lines ½” Dia Glycol tubing 

Beer Lines:  Max 4-off 3/8” Dia  Beer line tubing 

Input beer line connection is made on top of the tank onto John Guest 3/8” Superseal flowbend 

connection. 

Output beer line connection is made inside the tank onto John Guest 3/8” Superseal flowbend 

connections.  

6.6  Plumbing the Drain 

The 19mm overflow drain tube exiting from the RH Pump Panel of the unit should be plumbed to a 

suitable drain, installation in accordance with AS/NZS 3500.1 and AS/NZS 3500.2.  

6.7 Filling 

Unit 

 

Glycol

 - Remove Chiller lid and fill the tank with glycol/water mixture of 30% (refer to chart on page 

12 for details) until mixture flows out overflow tube. 

Summary of Contents for Lancer Polaris Beer Superchiller

Page 1: ...lancerbeverage com Installation Operation Service Manual Polaris Beer Superchiller 230V 50Hz...

Page 2: ...Location 6 6 4 Mounting Chiller 7 6 5 Connecting Python 7 6 6 Plumbing the Drain 7 6 7 Filling Unit 7 6 8 Electrical Connection 8 6 9 Commissioning 8 6 10 Purge System 8 7 Thermostat Carel Pjeasy The...

Page 3: ...SW Melbourne VIC Brisbane QLD Perth WA and Auckland New Zealand 3 Our Products Hoshizaki Lancer specialises in the design engineering manufacture and marketing of beverage dispensing and Heat Recovery...

Page 4: ...800 Grams R134a Tank 72 litres 72 litres 72 litres Ice bank Weight 18 kg 18 kg 18 kg Construction Stainless Steel Stainless Steel Stainless Steel 4 3 Models S4E POLARIS SPC17 Chiller with SPC17 Pump...

Page 5: ...ution notes throughout this manual To prevent personal injury or damage to the machine these alerts must be strictly adhered too Warning Alerts to a potentially hazardous situation that if not avoided...

Page 6: ...must be made with the carrier Upon receiving units from the delivering carrier carefully inspect shipping crate for visible indication s of damage If damage exists have carrier note damage on bill of...

Page 7: ...l on a flat level surface using adjustable legs or casters Optional Caution Chiller operational weight is 157 179kg ensure that all supporting structures are certified for this loading by a registered...

Page 8: ...hiller power supply lead to an appropriate 3 pin socket outlet and switch on Compressor condenser fans and pump agi motor should all operate On initial start up remove the pump plug to allow the tank...

Page 9: ...nd DOWN keys for 5 seconds In case of probe 2 failure the antifreeze alarm function is inhibited and regulation is still performed If AF parameter is set to its minimum value the alarm function is inh...

Page 10: ...xt parameter To exit from programming mode press the SET key for 3 seconds or wait 60 seconds without pressing any keys for the unit to time out 7 2 3 Eco Mode In the ECO mode an offset is added to th...

Page 11: ...arm function is inhibited and regulation is still performed If AF parameter is set to its minimum value the alarm function is inhibited rt F Time in hours of max min temperatures logging rH F Highest...

Page 12: ...lue Press the UP or DOWN key to change its value Press the SET key to store the new value and move to the next parameter To exit from programming mode press the PRG key for 5 seconds or wait 60 second...

Page 13: ...beer system is carried out including keg couplers beer lines chiller coils pythons founts and taps 9 1 2 Monthly Disconnect the machine from the power supply Remove the condenser filter and rinse in w...

Page 14: ...ly as product may vary 013a 25 November 2013 9 1 3 Yearly Disconnect the machine from the power supply Check interior of the tank clean product coils and evaporator if necessary to remove any accumula...

Page 15: ...15 of 23 Hoshizaki Lancer reserve the right to change specifications without notice Part No 68000200 Images are for illustration purposes only as product may vary 013a 25 November 2013 10 Electrical C...

Page 16: ...ge com Page 16 of 23 Hoshizaki Lancer reserve the right to change specifications without notice Part No 68000200 Images are for illustration purposes only as product may vary 013a 25 November 2013 10...

Page 17: ...0Hz lancerbeverage com Page 17 of 23 Hoshizaki Lancer reserve the right to change specifications without notice Part No 68000200 Images are for illustration purposes only as product may vary 013a 25 N...

Page 18: ...uate system and if necessary fit burnout drier to industry standards Compressor short cycling on thermal overload frequent starting and stopping of the compressor while control contacts remain closed...

Page 19: ...n For both systems the liquid line probe from the Hydra control provides High Temp protection for the refrigeration system The following test is to determine if the icebank level control is operating...

Page 20: ...433 ELECTRICAL BOX LID POLARIS 6 83000278 CONTROL LEVEL I B HYDRA R2 7a 83000184 PJ EASY OEM CONTROL KIT 7b 83000371 IR33 CONTROL KIT 8 95000642 LOUVRE KMD 0101AA 8a 95000641 FILTER 2 OF REQUIRED 9 61...

Page 21: ...Hz lancerbeverage com Page 21 of 23 Hoshizaki Lancer reserve the right to change specifications without notice Part No 68000200 Images are for illustration purposes only as product may vary 013a 25 No...

Page 22: ...Labour Lancer will not normally cover any labour costs associated with a warranty claim Subject to the approval of the Divisional Sales Manager Lancer may choose to reimburse the customer for some or...

Page 23: ...lly frosts Check all tube work for rubbing e g discharge line liquid line TX capillary Condenser not touching divider panel or grille Agitator blades tight and not touching coils cradle Overflow pipe...

Reviews: