Polaris Beer Superchiller™
230V / 50Hz
lancerbeverage.com
Page 7 of 23
Hoshizaki Lancer reserve the right to change specifications without notice.
Part No: 68000200
Images are for illustration purposes only as product may vary.
013a – 25 November 2013
Caution
The Chiller is not suitable for use in subfreezing temperatures.
To prevent damage to the water supply line, turn off and drain
unit when air temperature is below zero.
The Chiller should be located in a well-ventilated, firm, level location close to dispenser, water
and electrical supplies, with easy access for servicing
SPC version Chillers are intended for use in the bar area.
SPK2-11 version chillers are intended for use in a non temp controlled storage area.
Ensure sufficient clearance around Chiller to allow good fresh air circulation through the
condenser – allow at least 200mm at rear, sides and top, with the front unobstructed.
Installation should only be performed by a qualified and competent technician.
6.4
Mounting Chiller
Install on a flat, level surface using adjustable legs or casters (Optional).
Caution
Chiller operational weight is 157/179kg; ensure that all
supporting structures are certified for this loading by a
registered Mechanical Engineer.
Supporting structure must be securely fixed to floors or walls.
6.5
Connecting Python
Connect Python to Chiller and Dispenser.
Caution
NOTE: The Chiller is rated to operate with a maximum of 30m of
python connected.
Exceeding manufacturer’s ratings may cause damage to the
Chiller and void warranty.
Python Details
Recirculation Lines ½” Dia Glycol tubing
Beer Lines: Max 4-off 3/8” Dia Beer line tubing
Input beer line connection is made on top of the tank onto John Guest 3/8” Superseal flowbend
connection.
Output beer line connection is made inside the tank onto John Guest 3/8” Superseal flowbend
connections.
6.6 Plumbing the Drain
The 19mm overflow drain tube exiting from the RH Pump Panel of the unit should be plumbed to a
suitable drain, installation in accordance with AS/NZS 3500.1 and AS/NZS 3500.2.
6.7 Filling
Unit
Glycol
- Remove Chiller lid and fill the tank with glycol/water mixture of 30% (refer to chart on page
12 for details) until mixture flows out overflow tube.