![Hoshizaki KMD-901MAH Service Manual Download Page 20](http://html1.mh-extra.com/html/hoshizaki/kmd-901mah/kmd-901mah_service-manual_2164793020.webp)
20
3. Controls and Adjustments
a) Default Dip Switch Settings
The dip switches are factory-adjusted to the following positions:
S4 Dip Switch
Dip Switch No.
1
2
3
4
5
6
7
8
9
10
KMD-901MAH OFF OFF OFF ON ON ON ON OFF OFF OFF
KMD-901MWH OFF OFF OFF ON ON ON ON OFF OFF OFF
KMD-901MRH OFF OFF OFF ON ON ON ON OFF OFF OFF
S5 Dip Switch (Do Not Adjust)
Dip Switch No.
1
2
3
4
5
KMD-901MAH OFF OFF OFF OFF OFF
KMD-901MWH OFF OFF OFF OFF OFF
KMD-901MRH OFF OFF OFF OFF OFF
b) Harvest Timer (S4 dip switch 1 & 2)
The harvest timer starts counting when the thermistor reads 48°F (9°C) at the evaporator
outlet. No adjustment is required under normal use, as the harvest timer is adjusted to
the suitable position. However, a setting longer than the factory setting may be advised
in cases where the flush provided at harvest needs to be prolonged for extra cleaning.
Before changing this setting, call the HOSHIZAKI Technical Support Department at
1-800-233-1940 for recommendations. Keep in mind that setting the harvest timer to a
longer setting will decrease 24 hour production.
Dip Switch Setting
Time
(seconds)
No. 1
No. 2
OFF
OFF
60
ON
OFF
90
OFF
ON
120
ON
ON
180
S4 Dip Switch
Freeze Timer (9 & 10)
Pump-Out Frequency Control (5 & 6)
Pump-Out Timer - Do not adjust (3 & 4)
Harvest Timer (1 & 2)
Normally off (8)
Do not adjust (7)