![Hoshizaki KMD-460MAJ Instruction Manual Download Page 18](http://html1.mh-extra.com/html/hoshizaki/kmd-460maj/kmd-460maj_instruction-manual_2164777018.webp)
18
1. Icemaker
Icemaker Water
Supply Inlet
Minimum Icemaker
Water Supply Line Size
Icemaker Drain
Outlet
Minimum Icemaker
Drain Line Size
1/2" Female Pipe
Thread (FPT)
1/4" Nominal ID
Copper Water Tubing or
Equivalent
3/4" Female Pipe
Thread (FPT)
3/4" Nominal
ID Hard Pipe or
Equivalent
• An icemaker water supply line shut-off valve and drain valve must be installed.
• Be sure there is sufficient extra water supply line and drain line for the appliance to be
pulled out for service.
Fig. 8
Icemaker
2" (5-cm) air gap
Floor Drain
Ice
Storage
Bin
Model Shown:
KMD-460MAJ
Minimum 3/4" Nominal ID
Hard Pipe or Equivalent
Air-Cooled and Remote Models
Drain Valve
Shut-Off Valve
Separate piping to approved
drain. Leave a 2" (5-cm)
vertical air gap between the
end of each pipe and the
drain.
Be sure there is sufficient
extra water supply line and
drain line for the appliance
to be pulled out for service.
Minimum 1/4" Nominal ID Copper
Water Tubing or Equivalent
Icemaker
Water Supply
Inlet
1/2" FPT
Bin Drain Outlet
3/4" FPT
Icemaker
Drain Outlet
3/4" FPT
Vent Tube