3. Controls and Adjustments
CAUTION
Dip switches are factory set. Failure to maintain factory settings may adversely
affect performance and warranty coverage. For more information, contact
Hoshizaki Technical Support at 1-800-33-1940.
a) Default Dip Switch Settings
The dip switches are factory-adjusted to the following positions:
Model
S4 Dip Switch
1
3
4
5
6
7
8
9
10
KM1601SRH350
ON OFF OFF OFF ON ON OFF OFF OFF OFF
KM1900SAH350
OFF OFF OFF OFF OFF OFF OFF OFF ON OFF
KM2100SRH350
ON OFF ON ON OFF OFF OFF OFF ON OFF
Freeze Timer (9 & 10)
Pump-Out Frequency
Control (5 & 6)
Pump-Out Timer (3 & 4)
Harvest Timer (1 & )
S4 Dip Switch
Normally off (7 & 8)
b) Harvest Timer (S4 dip switch 1 & 2)
The harvest timer starts counting when the thermistor reads 48°F (9°C) at the evaporator
outlet. No adjustment is required under normal use, as the harvest timer is adjusted to
the suitable setting. However, a setting longer than the factory setting may be advised
in cases where the flush provided at harvest needs to be prolonged for extra cleaning.
Before changing this setting, contact Hoshizaki Technical Support at 1-800-33-1940
for recommendations. Keep in mind that setting the harvest timer to a longer setting will
decrease 4 hour production.
S4 Dip Switch Setting
Time
(seconds)
No. 1
No.
OFF
OFF
60
ON
OFF
90
OFF
ON
10
ON
ON
180