30
C. Performance Data
1. KM-515MAH (air-cooled)
Note:
1. Pressure data is recorded at 5 minutes into freezing cycle. The data not in
bold
should be used for reference only.
2. We reserve the right to make changes in specifications and design without prior
notice.
70/21
501
227
482
218
447
203
80/27
486
221
456
207
416
189
90/32
482
218
435
197
396
180
lbs./day kg./day
100/38
472
214
426
193
361
164
70/21
80/27
90/32
watts
100/38
70/21
188
0.71
162
0.61
147
0.56
80/27
168
0.64
128
0.48
124
0.47
90/32
162
0.61
99
0.38
90
0.34
gal./day m
3
/day
100/38
132
0.50
97
0.37
82
0.31
70/21
80/27
90/32
min.
100/38
70/21
80/27
90/32
min.
100/38
70/21
226
15.9
250
17.6
278
19.5
80/27
244
17.2
282
19.8
306
21.5
90/32
250
17.6
308
21.7
335
23.5
PSIG kg/cm
2
G
100/38
254
17.8
314
22.1
359
25.2
70/21
45
3.2
49
3.5
54
3.8
80/27
48
3.4
55
3.8
60
4.2
90/32
49
3.5
59
4.1
64
4.5
PSIG kg/cm
2
G
100/38
50
3.5
60
4.2
69
4.9
9,600 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
27
33
27
28
32
27
30
2.7
4.4
3.4
3.9
3.2
2.7
4.0
26
APPROXIMATE ICE
PRODUCTION PER 24 HR.
APPROXIMATE ELECTRIC
CONSUMPTION
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
FREEZING CYCLE TIME
WATER TEMP. (ºF/ºC)
AMBIENT TEMP.
(ºF/ºC)
50/10
70/21
90/32
1011
1012
1055
1090
1095
980
1005
1012
30
33
35
37
1038
1071
1111
1130
HARVEST CYCLE TIME
HEAD PRESSURE
3.8
3.4
3.9
2.7
2.7
TOTAL HEAT OF REJECTION FROM CONDENSER
SUCTION PRESSURE
ENG.F-011.1.0205