![Hoshizaki KM-470AJ Instruction Manual Download Page 29](http://html.mh-extra.com/html/hoshizaki/km-470aj/km-470aj_instruction-manual_2164662029.webp)
ENGLISH
27
Cleaning
4) Remove the front insulation panel, then slide the cube guide to the right. Remove the
rubber cap and sleeve covering the overflow pipe. See Fig. 6. Unscrew the overflow
pipe. After the water tank has drained, reconnect the overflow pipe. Replace the rubber
hose, overflow cap, cube guide, and front insulation panel.
NOTICE! Make sure the
O-ring is attached to the bottom of the overflow pipe and be careful not to cross
thread the overflow pipe.
5) To fill the water tank, move the control switch to the "ICE" position, then replace the
front panel. After 3.5 min., remove the front panel, then move the control switch to the
"OFF" position.
6) Remove the front insulation panel, then pour 887 ml of Hoshizaki "Scale Away" or the
other recomended Hoshizaki sanitizer as derected into the water tank. Replace the
front insulation panel. Turn the cleaning valve to the left until completely vertical (open).
7)
NOTICE!
To avoid excessive foaming, wait 1 min. before proceeding.
After 1 min., move the control switch to the "WASH" position, then replace the front
panel.
8) After 30 min., remove the front panel, then move the control switch to the "OFF"
position.
9) Remove the front insulation panel, then slide the cube guide to the right. Remove the
rubber hose and overflow cap covering the overflow pipe. Unscrew the overflow pipe.
After the water tank has drained, reconnect the overflow pipe. Replace the rubber
hose, overflow cap, cube guide, and front insulation panel.
10) In bad or severe water conditions, turn off the power supply, then remove, clean
(cleaning solution = 5 oz. Hoshizaki "Scale Away" per gallon of warm water), rinse,
and replace t he cube guides, float switch, water supply tubes, spray tubes, and spray
guides; turn on the power supply when complete. Otherwise, continue to step 11..
Cleaning Rinse
11) Turn the cleaning valve to the right until completely horizontal (closed). Move the control
switch to the "ICE" position, then replace the front panel. After 3.5 min., remove the
front panel, then move the control switch to the "OFF" position. Note: The icemaker will
not operate unless the cleaning valve is completely closed.
12) Turn the cleaning valve to the left until completely vertical (open). Move the control
switch to the "WASH" position, then replace the front panel. After 5 min., remove the
front panel, then move the control switch to the "OFF" position.
13) Remove the front insulation panel, then slide the cube guide to the right. Remove the
rubber hose and overflow cap covering the overflow pipe. Unscrew the overflow pipe. After
the water tank has drained, reconnect the overflow pipe. Replace the rubber hose, overflow
cap, cube guide, and front insulation panel.