41
9. Pump-Out Pump Motor Direction (S5 dip switch 1)
NOTICE
Do not adjust. This must be left in the factory default position or the icemaker will
not operate correctly.
The pump-out pump motor direction setting determines pump motor rotation during
pump-out.
On models with a drain valve pump motor rotation doesn't change at pump-out.
Pump motor rotates in forward direction and drain valve is energized for pump-out.
On models with a check valve, pump motor rotation reverses at pump-out.
Pump motor rotates in reverse direction and opens check valve for pump-out.
S5 Dip Switch Setting
Pump-Out Components
No. 1
OFF
Pump Motor Forward Rotation and Drain Valve
ON
Pump Motor Reverse Rotation and Check Valve
10. Refill Counter (S5 dip switch 2 and 3)
NOTICE
Do not adjust. These must be left in the factory default position or the icemaker will
not operate correctly.
S5 Dip Switch Setting
Refill
Counter
No. 2
No. 3
OFF
OFF
0
OFF
ON
1 refill
ON
OFF
9 refills
ON
ON
10 refills
11. Minimum Harvest Time (S5 dip switch 4)
NOTICE
Factory set for proper operation. Do not adjust. Adjustment outside the factory
default setting may result in damage to the appliance.
S5 Dip Switch Setting
Minimum
Harvest Timer
No. 4
OFF
120 sec.
ON
70 sec.
Summary of Contents for KM-350MAJ
Page 58: ...58 7 KM 660MWJ DATA PENDING ...