6) Remove the front insulation panel, then pour 14 fl. oz. (414 ml) of Hoshizaki "Scale
Away" into the water tank. Replace the front insulation panel. Turn the cleaning valve to
the left until completely vertical (open).
7)
NOTICE!
To avoid excessive foaming, wait 1 min. before proceeding.
After 1 min., move the control switch to the "WASH" position, then replace the front
panel.
8) After 30 min., remove the front panel, then move the control switch to the "OFF"
position.
9) Disconnect the water pump hose. After the water tank has drained, reconnect the water
pump hose.
10) In bad or severe water conditions, turn off the power supply, then remove, clean
(cleaning solution = 5 oz. Hoshizaki "Scale Away" per gallon of warm water), rinse, and
replace the cube guide, float switch, water supply tubes, spray tubes, and spray guides;
turn on the power supply when complete. Otherwise, continue to step 11.
Cleaning Rinse
11) Turn the cleaning valve to the right until completely horizontal (closed). Move the control
switch to the "ICE" position, then replace the front panel. After 3 min., remove the front
panel, then move the control switch to the "OFF" position. Note: The icemaker will not
operate unless the cleaning valve is completely closed.
12) Turn the cleaning valve to the left until completely vertical (open). Move the control
switch to the "WASH" position, then replace the front panel. After 5 min., remove the
front panel, then move the control switch to the "OFF" position.
13) Disconnect the water pump hose. After the water tank has drained, reconnect the water
pump hose.
Sanitizing
14) To fill the water tank, turn the cleaning valve to the right until completely horizontal
(closed). Move the control switch to the "ICE" position, then replace the front panel.
After 3 min., remove the front panel, then move the control switch to the "OFF" position.
15) Remove the front insulation panel, then pour .78 fl. oz. (23 ml) of an 8.25% sodium
hypochlorite solution (chlorine bleach) into the water tank. Replace the front insulation
panel. Turn the cleaning valve to the left until completely vertical (open).
IMPORTANT!
Use regular bleach with no additives. Using a bleach with additives causes
excessive foaming during sanitizing, reducing the effectiveness of sanitizing.
16)
NOTICE!
To avoid excessive foaming, wait 1 min. before proceeding.
After 1 min., move the control switch to the "WASH" position, then replace the front
panel.
17) After 45 min., remove the front panel, then move the control switch to the "OFF"
position.
18) Disconnect the water pump hose. After the water tank has drained, reconnect the water
pump hose.