82
23a. KM-1601MRH3 with URC-21F
Specification Sheet
AC SUPPLY VOLTAGE
208-230/60/3
AMPERAGE
8.4 A ( 5 Min. Freeze AT 104°F / WT 80°F)
MINIMUM CIRCUIT AMPACITY
20 A
MAXIMUM FUSE SIZE
20 A
ELECTRIC & WATER CONSUMPTION 90/70°F
70/50°F
ELECTRIC W (kWH/100 lbs.)
2640(4.6)
2410(3.9)
WATER gal./24HR (gal./100 lbs.)
267(19.2)
491(33.4)
ICE PRODUCTION PER CYCLE
28.0 lbs. (12.7 kg) 1440 pcs.
BIN CONTROL SYSTEM
Thermostat
TOTAL REFRIGERANT CHARGE
R-404A, 24 lb. 4.0 oz. (11,000g)
REFRIGERANT CHARGE by UNIT
Icemaker 14 lbs. 8.8 oz. Cond. Unit 9 lb. 11.2 oz.
Performance Data
70/21
1471
667
1448
657
1354
614
80/27
1453
659
1417
643
1290
585
90/32
1448
657
1392
631
1277
579
lbs./day kg./day
100/38
1408
639
1365
619
1171
531
70/21
80/27
90/32
watts
100/38
70/21
491
1.86
426
1.61
368
1.39
80/27
441
1.67
339
1.28
299
1.13
90/32
426
1.61
267
1.01
218
0.83
gal./day m3/day
100/38
340
1.29
256
0.97
173
0.66
70/21
80/27
90/32
min.
100/38
70/21
80/27
90/32
min.
100/38
70/21
203
14.3
218
15.3
242
17.0
80/27
214
15.1
237
16.7
263
18.5
90/32
218
15.3
253
17.8
279
19.6
PSIG kg/cm2G
100/38
224
15.7
259
18.2
303
21.3
70/21
38
2.7
40
2.8
42
2.9
80/27
40
2.8
43
3.0
44
3.1
90/32
40
2.8
45
3.2
47
3.3
PSIG kg/cm2G
100/38
40
2.8
45
3.2
48
3.4
CONDENSER VOLUME
441 CU. IN (URC-21F)
APPROXIMATE ICE PRODUCTION
PER 24 HR.
AMBIENT TEMP.
(ºF/ºC)
WATER TEMP. (ºF/ºC)
50/10
70/21
90/32
APPROXIMATE ELECTRIC
CONSUMPTION
2410
2477
2503
2461
2566
2555
2477
2640
2645
2460
2641
2650
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
FREEZING CYCLE TIME
23
24
26
23
25
27
24
27
29
24
27
31
HARVEST CYCLE TIME
5.7
4.9
4.4
5.1
3.9
3.6
4.9
3.1
2.7
TOTAL HEAT OF REJECTION FROM COMPRESSOR
3,200 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
4.0
3.0
2.3
HEAD PRESSURE
SUCTION PRESSURE
TOTAL HEAT OF REJECTION FROM CONDENSER
24,900 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
ENG.F-011.1.0205