F. Diagnostic Charts
1. No Ice Production
No Ice Production - Possible Cause
1. Power Supply
a) Off, blown fuse, or tripped breaker.
b) Not within specifications.
2. Fuse (Power Cord)
a) Blown.
3. Main Transformer
(230VAC/115VAC)
a) Coil winding open or shorted.
4. Fuse (Control Box)
a) Blown.
5. Thermostatic Bin Control
(KM-320MAH-E and
KM-650MAH-E
Aux. Code U-0 and Earlier;
KM-515MAH-E
Aux. Code U-1 and Earlier)
See "IV.C. Bin Control Check"
a) Tripped with bin filled with ice.
b) Ambient temperature too cool.
c) Set too warm.
d) Bulb out of position.
e) Open contacts, defective.
6. Control Switch
a) In "OFF" or "WASH" position.
b) Bad contacts.
7. High-Pressure Switch
a) Dirty condenser.
b) Fan motor not operating.
c) Refrigerant overcharged.
d) Bad contacts.
e) Refrigerant lines or components plugged.
8. Control Transformer
(115VAC/10.5VAC)
a) Coil winding open or shorted.
9. Control Board
See "IV.B. Control Board Check"
a) In alarm.
b) Yellow "BC OPEN" LED on (bin full).
c) Defective.
10. Mechanical Bin Control
(KM-320MAH-E and
KM-650MAH-E
Aux. Code U-1 and Later;
KM-515MAH-E
Aux. Code U-2 and Later)
See "IV.C. Bin Control Check"
a) Tripped with bin filled with ice.
b) Actuator does not move freely.
c) Defective.
11. Water Supply
a) Water supply off or improper water pressure.
b) External water filters clogged.
12. Inlet Water Valve
a) Screen or orifice clogged.
b) Coil winding open.
c) Water valve open in freeze cycle.
13. Float Switch
See "IV.D. Float Switch Check
and Cleaning"
a) Float does not move freely.
b) Defective.