27
6) Open the water regulating valve by using a screwdriver to pry up on the spring retainer
underneath the spring. While holding the valve open, blow out the condenser using the
compressed air or carbon dioxide supply until water stops coming out.
Note: Be sure to close the water regulating valve as before.
7) Close the condenser water supply line drain valve. If connected to a closed loop
system, also close the condenser return line drain valve.
8) Replace the left side and top panels in their correct positions.
IV. Disposal
The appliance contains refrigerant and must be disposed of in accordance with applicable
national, state, and local codes and regulations. Refrigerant must be recovered by properly
certifi ed service personnel.
IMPORTANT
The insulation foaming agent used for the unit body contains fl ammable gas
cyclopentane. With this in mind, dispose of the product properly.