BLACK
WARNING
ELECTRICAL CONNECTION
THIS UNIT MUST BE GROUNDED
Failure to properly ground or wire
this unit could result in death,
serious injury, or severe damage to
the icemaker.
The transformer’s voltage tap switch
must be positioned to match incoming
voltage at startup.
See diagram below.
4A5812-010
208-230/60/1
JUNCTION BOX
20
8-2
30
V
BROWN
L1
L2
WARNING
ELECTRICAL CONNECTION
THIS UNIT MUST BE GROUNDED
Failure to properly ground or wire
this unit could result in death,
serious injury, or severe damage
to the icemaker. The white lead
must be connected to the neutral
conductor of the power source.
See diagram below.
4A5700-010
208-230/60/1
(3 wire with neutral for 115V)
JUNCTION BOX
208-230
V
BLACK
BROWN
L1
L2
WHITE
N
115
-
120V
Fig. 7
BROWN
WARNING
ELECTRICAL CONNECTION
THIS UNIT MUST BE GROUNDED
Failure to properly ground or wire
this unit could result in death,
serious injury, or severe damage to
the icemaker.
This unit must be connected to a
three-phase power source.
The transformer’s voltage tap switch
must be positioned to match incoming
voltage at startup.
See diagram below.
208-230/60/3
4A5701-010
JUNCTION BOX
208-230
V
BLACK
L1
L3
RED
L2
208- 230V
208- 230V